aiqbench analysis
This research advances robotic manipulation by introducing a marker-free hand-eye calibration method that leverages RGB-D imaging and Lie algebra formulations to achieve superior convergence speed and accuracy. The approach significantly outperforms existing baselines in task space precision while eliminating the need for physical markers, streamlining deployment for serial manipulators via ROS 2 integration.
Hydra: Marker-Free RGB-D Hand-Eye Calibration
arXiv:2504.20584v2 Announce Type: replace Abstract: This work presents an RGB-D imaging-based approach to marker-free hand-eye calibration using a novel implementation of the iterative closest point (ICP) algorithm with a robust point-to-plane (PTP) objective formulated on a Lie algebra. Its applicability is demonstrated through comprehensive experiments using three well known serial manipulators and two RGB-D cameras. With only three randomly chosen robot configurations, our approach achieves approximately 90% successful calibrations, demonstrating 2-3x higher convergence rates to the global optimum compared to both marker-based and marker-free baselines. We also report 2 orders of magnitude faster convergence time (0.8 +/- 0.4 s) for 9 robot configurations over other marker-free methods. Our method exhibits significantly improved accuracy (5 mm in task space) over classical approaches (7 mm in task space) whilst being marker-free. The benchmarking dataset and code are open sourced under Apache 2.0 License, and a ROS 2 integration with robot abstraction is provided to facilitate deployment.
Abstract:This work presents an RGB-D imaging-based approach to marker-free hand-eye calibration using a novel implementation of the iterative closest point (ICP) algorithm with a robust point-to-plane (PTP) objective formulated on a Lie algebra. Its applicability is demonstrated through comprehensive experiments using three well known serial manipulators and two RGB-D cameras. With only three randomly chosen robot configurations, our approach achieves approximately 90% successful calibrations, demonstrating 2-3x higher convergence rates to the global optimum compared to both marker-based and marker-free baselines. We also report 2 orders of magnitude faster convergence time (0.8 +/- 0.4 s) for 9 robot configurations over other marker-free methods. Our method exhibits significantly improved accuracy (5 mm in task space) over classical approaches (7 mm in task space) whilst being marker-free. The benchmarking dataset and code are open sourced under Apache 2.0 License, and a ROS 2 integration with robot abstraction is provided to facilitate deployment.
Robotics (cs.RO); Computer Vision and Pattern Recognition (cs.CV)
arXiv:2504.20584 [cs.RO]
(or arXiv:2504.20584v2 [cs.RO] for this version)
https://doi.org/10.48550/arXiv.2504.20584 Focus to learn more arXiv-issued DOI via DataCite
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 246 words
Related coverage
Tracker-Free Robotic Ultrasound Calibration with a Spherical-Marker Phantom and Threshold-Free Center Localization
arXiv · Sep 22, 2026

[AINews] Reality Checks on AI News (Yegge shuts down Gas Town, Databricks’ +60% Astra cost)
Latent Space · Sep 17, 2026
DRHeC: Differentiable Rendering for Hand-Eye Calibration with RGB-Based Gradients
arXiv · Sep 30, 2026

[AINews] Meta Muse Wonder & Wonder Full: MSL’s Claude 5.5-tier Frontier Model
Latent Space · Oct 13, 2026