This research advances robotic ultrasound calibration by eliminating the need for external 3D trackers and hand-tuned intensity thresholds through an automated, threshold-free perception pipeline. The study demonstrates that a single spherical-marker phantom can achieve geometric accuracy comparable to multi-marker setups, simplifying the setup for clinical robotic imaging systems.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Tracker-Free Robotic Ultrasound Calibration with a Spherical-Marker Phantom and Threshold-Free Center Localization

arXiv3 min read

arXiv:2609.22483v1 Announce Type: new Abstract: Robotic ultrasound (US) calibration is essential for accurately relating US images to the robot coordinate system, but accurate and automated calibration remains challenging because existing methods often require complex phantoms or external 3D trackers. In this work, we develop a tracker-free robotic US calibration framework using a spherical-marker phantom and a highly automated perception pipeline for sphere-center localization. The proposed threshold-free image-processing method localizes the spherical feature based on each US image's intensity distribution, eliminating hand-tuned intensity thresholds and improving robustness across imaging settings without per-system retuning. Multi-pose observations of the spherical fiducial are then used to estimate the US-to-EE transformation without external tracking or prior localization of the sphere center in the robot base frame. We validate the proposed framework on a robotic US platform through repeated sphere scans and further assess the calibrated system using geometrically distinct phantoms with known CAD models. Across 12 cross-validation folds, single-marker calibration achieved sphere-center accuracy and precision of $1.75\pm0.51$ mm and $0.85\pm0.11$ mm, respectively, compared with $1.72\pm0.51$ mm and $0.84\pm0.12$ mm for three-marker calibration. Across the three reconstruction sets, the single-marker calibration yielded pooled post-registration point-to-surface MAE$\pm$SD values of $0.41\pm0.35$ mm for the cone and $0.50\pm0.41$ mm for the triangular prism, closely matching the three-marker results of $0.40\pm0.35$ mm and $0.48\pm0.40$ mm, respectively.

Abstract:Robotic ultrasound (US) calibration is essential for accurately relating US images to the robot coordinate system, but accurate and automated calibration remains challenging because existing methods often require complex phantoms or external 3D trackers. In this work, we develop a tracker-free robotic US calibration framework using a spherical-marker phantom and a highly automated perception pipeline for sphere-center localization. The proposed threshold-free image-processing method localizes the spherical feature based on each US image's intensity distribution, eliminating hand-tuned intensity thresholds and improving robustness across imaging settings without per-system retuning. Multi-pose observations of the spherical fiducial are then used to estimate the US-to-EE transformation without external tracking or prior localization of the sphere center in the robot base frame. We validate the proposed framework on a robotic US platform through repeated sphere scans and further assess the calibrated system using geometrically distinct phantoms with known CAD models. Across 12 cross-validation folds, single-marker calibration achieved sphere-center accuracy and precision of $1.75\pm0.51$ mm and $0.85\pm0.11$ mm, respectively, compared with $1.72\pm0.51$ mm and $0.84\pm0.12$ mm for three-marker calibration. Across the three reconstruction sets, the single-marker calibration yielded pooled post-registration point-to-surface MAE$\pm$SD values of $0.41\pm0.35$ mm for the cone and $0.50\pm0.41$ mm for the triangular prism, closely matching the three-marker results of $0.40\pm0.35$ mm and $0.48\pm0.40$ mm, respectively.

Robotics (cs.RO); Image and Video Processing (eess.IV)

arXiv:2609.22483 [cs.RO]

(or arXiv:2609.22483v1 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2609.22483 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 309 words