aiqbench analysis
This research introduces a novel vector magnetometry technique using nitrogen-vacancy centers and broadband microwave pulses, eliminating the need for external bias fields by measuring fields as low as 25 µT. The approach leverages orthogonally polarized pulses to resolve independent magnetic field components, with deep neural networks applied to simulated data to achieve sensitivities between 5 and 100 pT/√Hz. While currently validated via simulation, the method's potential to translate to experimental setups offers a significant advancement for high-precision magnetic sensing without auxiliary magnetic environments.
Vector Magnetometry with Broadband Microwave Fields in Nitrogen-Vacancy Centers in Diamond
arXiv:2606.02749v1 Announce Type: new Abstract: We present a novel method for full vector magnetometry using nitrogen-vacancy (NV) centers. In contrast to conventional optically detected magnetic resonance techniques, our method employs two distinct broadband microwave pulses and measures them after transmission through the NV sensor medium, thus capturing the line splitting of the ground state triplet due to the Zeeman effect. Two orthogonally polarized microwave pulses allow resolving all magnetic field components independently by reading out differently oriented NV centers. Simulated data is analyzed using deep neural networks, whose efficacy we expect to translate very well to experiments. Our method yields sensitivities between $5~\mathrm{pT}/\sqrt{\mathrm{Hz}}$ and $100~\mathrm{pT}/\sqrt{\mathrm{Hz}}$ across different magnetic field vector components, while achieving approximately $\mathrm{nT}$ accuracy at a signal-to-noise (SNR) ratio of $70~\mathrm{dB}$. By being capable of accurately measuring magnetic fields down to $25~\mathrm{\mu T}$, the need for a bias field beyond Earth's magnetic field is eliminated.
Abstract:We present a novel method for full vector magnetometry using nitrogen-vacancy (NV) centers. In contrast to conventional optically detected magnetic resonance techniques, our method employs two distinct broadband microwave pulses and measures them after transmission through the NV sensor medium, thus capturing the line splitting of the ground state triplet due to the Zeeman effect. Two orthogonally polarized microwave pulses allow resolving all magnetic field components independently by reading out differently oriented NV centers. Simulated data is analyzed using deep neural networks, whose efficacy we expect to translate very well to experiments. Our method yields sensitivities between $5~\mathrm{pT}/\sqrt{\mathrm{Hz}}$ and $100~\mathrm{pT}/\sqrt{\mathrm{Hz}}$ across different magnetic field vector components, while achieving approximately $\mathrm{nT}$ accuracy at a signal-to-noise (SNR) ratio of $70~\mathrm{dB}$. By being capable of accurately measuring magnetic fields down to $25~\mathrm{\mu T}$, the need for a bias field beyond Earth's magnetic field is eliminated.
Quantum Physics (quant-ph); Mesoscale and Nanoscale Physics (cond-mat.mes-hall)
arXiv:2606.02749 [quant-ph]
(or arXiv:2606.02749v1 [quant-ph] for this version)
https://doi.org/10.48550/arXiv.2606.02749 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 241 words
Related coverage
Wideband microwave resonator for NV center vector magnetometry
arXiv · Oct 12, 2026
Microwave-free vector magnetometry and crystal orientation determination with Nitrogen-Vacancy centers using Bayesian inference
arXiv · Jun 17, 2026

News
Quantum Computing Report · Jun 7, 2026
Unconditional full vector magnetometry using spin selectivity in Nitrogen Vacancy centers in diamond
arXiv · Oct 15, 2026