aiqbench analysis
This research presents a significant advancement in quantum sensing by enabling microwave-free vector magnetometry using Nitrogen-Vacancy centers, effectively eliminating heating issues caused by traditional electromagnetic fields. By leveraging Bayesian inference and cross-relaxation between differently oriented NV centers, the study achieves robust magnetic field reconstruction without requiring strict crystal alignment, paving the way for more practical solid-state sensors.
Microwave-free vector magnetometry and crystal orientation determination with Nitrogen-Vacancy centers using Bayesian inference
arXiv:2512.13835v2 Announce Type: replace Abstract: Nitrogen-vacancy (NV) centers in diamond provide a solid-state platform for quantum sensing. While optically detected magnetic resonance techniques offer high sensitivity, their reliance on microwaves introduces heating and stray electromagnetic fields that can perturb nearby samples. Optical approaches based on cross-relaxation between differently oriented NV centers remove this constraint but have so far required stringent alignment of the external field with crystallographic axes, restricting their practicality. Here we introduce a general framework for microwave-free vector magnetometry at near-zero field that leverages Bayesian inference to extract both the magnetic field vector and the NV orientation directly from photoluminescence maps. An analytical model of cross-relaxation resonances enables efficient inference under arbitrary field and orientation configurations, while naturally incorporating the discrete degeneracies of the NV symmetry. We experimentally demonstrate robust orientation determination and vector-field reconstruction, establishing a general route toward compact and alignment-free NV magnetometers for practical sensing applications.
Abstract:Nitrogen-vacancy (NV) centers in diamond provide a solid-state platform for quantum sensing. While optically detected magnetic resonance techniques offer high sensitivity, their reliance on microwaves introduces heating and stray electromagnetic fields that can perturb nearby samples. Optical approaches based on cross-relaxation between differently oriented NV centers remove this constraint but have so far required stringent alignment of the external field with crystallographic axes, restricting their practicality. Here we introduce a general framework for microwave-free vector magnetometry at near-zero field that leverages Bayesian inference to extract both the magnetic field vector and the NV orientation directly from photoluminescence maps. An analytical model of cross-relaxation resonances enables efficient inference under arbitrary field and orientation configurations, while naturally incorporating the discrete degeneracies of the NV symmetry. We experimentally demonstrate robust orientation determination and vector-field reconstruction, establishing a general route toward compact and alignment-free NV magnetometers for practical sensing applications.
arXiv:2512.13835 [quant-ph]
(or arXiv:2512.13835v2 [quant-ph] for this version)
https://doi.org/10.48550/arXiv.2512.13835 Focus to learn more arXiv-issued DOI via DataCite
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 235 words
Related coverage
Methods for traceable scanning magnetometry using single nitrogen vacancy centers in diamond: determining orientation, distance and localization
arXiv · Aug 6, 2026

Measurement incompatibility in Bayesian multiparameter quantum estimation
Quantum Journal · Aug 13, 2026

News
Quantum Computing Report · Jun 7, 2026

Quantum simulator shows matter emerging from field: 70-year-old calculations don't match
ixbt.com · Sep 25, 2026