aiqbench analysis
This research advances nitrogen-vacancy (NV) center thermometry by exploiting bright-dark state mixing to recover temperature-sensitive signals in near-degenerate regimes where conventional protocols fail. By utilizing a four-phase quadrature readout and low-field dynamical decoupling, the study enables robust spatially resolved temperature measurements without requiring magnetic bias fields or high microwave power. These findings are critical for deploying quantum sensors in resource-constrained biological or mobile environments.
Thermometry in Near-Degenerate Nitrogen-Vacancy Ensembles Enabled by Bright-Dark-State Mixing
arXiv:2609.22661v1 Announce Type: new Abstract: Nitrogen-vacancy (NV) centers have emerged as a highly sensitive platform for spatially resolved temperature measurements. When the $\lvert0\rangle\to\lvert+1\rangle$ and $\lvert0\rangle\to\lvert-1\rangle$ transitions are nearly degenerate and the Rabi frequency is comparable to the transition splitting, the spin dynamics encountered during pulsed protocols for temperature measurement can significantly alter the intended accumulation of temperature-dependent phase. We investigate these triplet ($\lvert0\rangle$, $\lvert\pm1\rangle$) spin dynamics and their effect on pulsed thermometry protocols under these conditions. We find that the conventional thermal-echo timing produces negligible temperature-sensitive signal amplitudes at the common-mode detuning. However, we find that the nominal spin-echo timing produces resolvable oscillations at the common-mode detuning, leading to a strong temperature-sensitive carrier signal. This departure from the expected protocol behavior is qualitatively captured by an ensemble model of the triplet dynamics, which supports significant dark-state leakage as a plausible mechanism for the temperature-sensitive response. This mixing-enabled thermal echo uses a four-phase quadrature readout that resolves the signed oscillation frequency and is validated using independent sweeps of the microwave carrier frequency and fluid temperature. We further assess the ability of a four-refocusing-pulse (LDD4B) low-field dynamical-decoupling sequence to extend the NV coherence and find that while the echo retains a sensitivity to common-mode detuning, the effective phase-accumulation interval corresponds to approximately half the total evolution time. These findings could support the use of pulsed NV thermometry in biological or mobile applications where applying magnetic bias fields is impractical and microwave power may be limited.
Abstract:Nitrogen-vacancy (NV) centers have emerged as a highly sensitive platform for spatially resolved temperature measurements. When the $\lvert0\rangle\to\lvert+1\rangle$ and $\lvert0\rangle\to\lvert-1\rangle$ transitions are nearly degenerate and the Rabi frequency is comparable to the transition splitting, the spin dynamics encountered during pulsed protocols for temperature measurement can significantly alter the intended accumulation of temperature-dependent phase. We investigate these triplet ($\lvert0\rangle$, $\lvert\pm1\rangle$) spin dynamics and their effect on pulsed thermometry protocols under these conditions. We find that the conventional thermal-echo timing produces negligible temperature-sensitive signal amplitudes at the common-mode detuning. However, we find that the nominal spin-echo timing produces resolvable oscillations at the common-mode detuning, leading to a strong temperature-sensitive carrier signal. This departure from the expected protocol behavior is qualitatively captured by an ensemble model of the triplet dynamics, which supports significant dark-state leakage as a plausible mechanism for the temperature-sensitive response. This mixing-enabled thermal echo uses a four-phase quadrature readout that resolves the signed oscillation frequency and is validated using independent sweeps of the microwave carrier frequency and fluid temperature. We further assess the ability of a four-refocusing-pulse (LDD4B) low-field dynamical-decoupling sequence to extend the NV coherence and find that while the echo retains a sensitivity to common-mode detuning, the effective phase-accumulation interval corresponds to approximately half the total evolution time. These findings could support the use of pulsed NV thermometry in biological or mobile applications where applying magnetic bias fields is impractical and microwave power may be limited.
arXiv:2609.22661 [quant-ph]
(or arXiv:2609.22661v1 [quant-ph] for this version)
https://doi.org/10.48550/arXiv.2609.22661 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 329 words
Related coverage
Towards Quantum Limited Spatial Resolution of NV-Diamond Magnetometry
arXiv · Jun 16, 2026
Optimal control for duty-cycle-limited interferometry with single-NV centers
arXiv · Sep 21, 2026

Researchers Measure Sheared Quantum Noise in Diamond Spins
Quantum Zeitgeist · Sep 17, 2026

Measurement incompatibility in Bayesian multiparameter quantum estimation
Quantum Journal · Aug 13, 2026