This research demonstrates how decoherence-aware coherent control sequences can significantly enhance the thermometric sensitivity of single nitrogen-vacancy center sensors in duty-cycle-limited regimes. By concentrating phase accumulation near the end of the sequence, the proposed method achieves a 57-60% gain in Fisher information compared to standard Ramsey interrogation under optical-dose constraints. These findings offer a practical pathway to improve nanoscale sensing performance in soft and biological environments where measurement overhead dominates experimental time.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Optimal control for duty-cycle-limited interferometry with single-NV centers

arXiv3 min read

arXiv:2609.21501v1 Announce Type: new Abstract: Stimulus-responsive hydrogels convert temperature changes into magnetic-field shifts detectable by nitrogen-vacancy (NV) centers, enabling nanoscale thermometry in soft and biological environments. Existing hydrogel-nanodiamond demonstrations rely on NV ensembles, whose high photon throughput is accompanied by gradient-induced inhomogeneous broadening, while idealized single-NV projections assume high-fluence fluorescence/ODMR readout. Here we study a pulsed single-NV route for the same class of sensors and ask whether decoherence-aware coherent control can improve thermometric performance over optimized Ramsey interrogation at equal detected-photon budget. Using a sigmoidal volume-phase-transition model, dipolar magnetic transduction, and Lindblad master-equation simulations, we find a reproducible 25-27% per-shot sensitivity gain over optimized Ramsey, i.e., a 57-60% gain in Fisher information (1.57-1.60). The same gain carries over to the photon-normalized Fisher information. The rate gain is governed by the measurement duty cycle, the fraction of the experimental cycle spent accumulating signal rather than initializing, reading out or waiting, and becomes largest when the overhead or optical-dose constraint dominates the cycle time. The optimized trajectories reveal a response-shaping mechanism in which phase accumulation is concentrated near the end of the sequence, and a closed-form depth-two solution reproduces the numerical optimum and exhibits that mechanism analytically. The advantage is most pronounced when the dephasing time is short compared with the measurement overhead or dose-limited waiting time, which is the operating regime targeted by hydrogel-transduced single-spin biosensing.

Abstract:Stimulus-responsive hydrogels convert temperature changes into magnetic-field shifts detectable by nitrogen-vacancy (NV) centers, enabling nanoscale thermometry in soft and biological environments. Existing hydrogel-nanodiamond demonstrations rely on NV ensembles, whose high photon throughput is accompanied by gradient-induced inhomogeneous broadening, while idealized single-NV projections assume high-fluence fluorescence/ODMR readout. Here we study a pulsed single-NV route for the same class of sensors and ask whether decoherence-aware coherent control can improve thermometric performance over optimized Ramsey interrogation at equal detected-photon budget. Using a sigmoidal volume-phase-transition model, dipolar magnetic transduction, and Lindblad master-equation simulations, we find a reproducible 25-27% per-shot sensitivity gain over optimized Ramsey, i.e., a 57-60% gain in Fisher information (1.57-1.60). The same gain carries over to the photon-normalized Fisher information. The rate gain is governed by the measurement duty cycle, the fraction of the experimental cycle spent accumulating signal rather than initializing, reading out or waiting, and becomes largest when the overhead or optical-dose constraint dominates the cycle time. The optimized trajectories reveal a response-shaping mechanism in which phase accumulation is concentrated near the end of the sequence, and a closed-form depth-two solution reproduces the numerical optimum and exhibits that mechanism analytically. The advantage is most pronounced when the dephasing time is short compared with the measurement overhead or dose-limited waiting time, which is the operating regime targeted by hydrogel-transduced single-spin biosensing.

arXiv:2609.21501 [quant-ph]

(or arXiv:2609.21501v1 [quant-ph] for this version)

https://doi.org/10.48550/arXiv.2609.21501 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 311 words

Related coverage