aiqbench analysis
This research introduces a spatial-temporal transformer framework that significantly improves remote heart-rate estimation accuracy under varying lighting conditions, reducing mean absolute error by 93.6% compared to existing baselines. By integrating illumination augmentation and hybrid temporal-frequency supervision, the method effectively addresses a critical deployment barrier for robot-mounted vision systems in uncontrolled environments. The approach offers a robust solution for physiological sensing in service and assistive robots, enabling reliable non-contact monitoring where previous models failed.
Illumination-Robust Camera-Based Heart-Rate Estimation for Physiological Sensing in Robots
arXiv:2606.12378v1 Announce Type: cross Abstract: Physiological awareness is important for service, social, and assistive robots that interact with humans in everyday environments. Remote photoplethysmography (rPPG) enables non-contact heart-rate (HR) estimation from an RGB camera, making it a promising sensing modality for robot-mounted vision systems. However, illumination variation remains a major barrier to robust deployment. This paper presents an end-to-end spatial-temporal transformer framework for remote HR estimation on a new dataset with varied illumination. Our estimator integrates PRNet-based 3D face alignment, clip-level illumination augmentation, the Residual Temporal Standardization Module, and controlled hybrid temporal-frequency supervision. The training objective combines a Soft-Shifted Pearson waveform loss with a spectral Kullback-Leibler divergence loss, where a tuned weight ($\mathbf{\beta}$) controls the contribution of frequency-domain heart-rate guidance. Experiments on a static all-level mix protocol covering three illumination levels show that $\mathbf{\beta}=5$ provides the strongest result among the tested beta settings, achieving a best-run HR mean absolute error (MAE) of 0.79 bpm and an HR correlation of 0.982. Compared with the PhysFormer baseline evaluated on our dataset, our estimator reduces HR MAE by 93.6 %, while increasing HR correlation from 0.088 to 0.982, making it usable when illumination varies.
Abstract:Physiological awareness is important for service, social, and assistive robots that interact with humans in everyday environments. Remote photoplethysmography (rPPG) enables non-contact heart-rate (HR) estimation from an RGB camera, making it a promising sensing modality for robot-mounted vision systems. However, illumination variation remains a major barrier to robust deployment. This paper presents an end-to-end spatial-temporal transformer framework for remote HR estimation on a new dataset with varied illumination. Our estimator integrates PRNet-based 3D face alignment, clip-level illumination augmentation, the Residual Temporal Standardization Module, and controlled hybrid temporal-frequency supervision. The training objective combines a Soft-Shifted Pearson waveform loss with a spectral Kullback-Leibler divergence loss, where a tuned weight ($\mathbf{\beta}$) controls the contribution of frequency-domain heart-rate guidance. Experiments on a static all-level mix protocol covering three illumination levels show that $\mathbf{\beta}=5$ provides the strongest result among the tested beta settings, achieving a best-run HR mean absolute error (MAE) of 0.79 bpm and an HR correlation of 0.982. Compared with the PhysFormer baseline evaluated on our dataset, our estimator reduces HR MAE by 93.6 %, while increasing HR correlation from 0.088 to 0.982, making it usable when illumination varies.
Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)
arXiv:2606.12378 [cs.CV]
(or arXiv:2606.12378v1 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2606.12378 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 286 words
Related coverage

The Apple Watch Series 12 is the start of a new wearable era
The Verge · Sep 17, 2026

Towards passive heart health monitoring via smartphone camera
Google Research · Jun 4, 2026
Dense Soft Weighting for Radar Ego-Velocity Estimation
arXiv · Jul 30, 2026
Robust Photoplethysmography Signal Denoising via Mamba Networks
arXiv · Sep 23, 2026