Skip to content
aiqbench takeMachine Learning

aiqbench analysis

This paper introduces DPNet, a Mamba-based architecture specifically engineered to denoise photoplethysmography (PPG) signals in wearable devices by effectively modeling temporal dynamics amidst motion artifacts. By combining an SI-SDR loss function with HR-guided supervision, the model achieves superior waveform fidelity and heart rate accuracy compared to conventional filtering and existing neural approaches on the BIDMC dataset. The work highlights the practical viability of state-space models like Mamba for enhancing signal integrity in real-world healthcare monitoring scenarios.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Robust Photoplethysmography Signal Denoising via Mamba Networks

arXiv2 min read

arXiv:2510.11058v2 Announce Type: replace Abstract: Photoplethysmography (PPG) is widely used in wearable health monitoring, but its reliability is often degraded by noise and motion artifacts, limiting downstream applications such as heart rate (HR) estimation. This paper presents a deep learning framework for PPG denoising with an emphasis on preserving physiological information. In this framework, we propose DPNet, a Mamba-based denoising backbone designed for effective temporal modeling. To further enhance denoising performance, the framework also incorporates a scale-invariant signal-to-distortion ratio (SI-SDR) loss to promote waveform fidelity and an auxiliary HR predictor (HRP) that provides physiological consistency through HR-based supervision. Experiments on the BIDMC dataset show that our method achieves strong robustness against both synthetic noise and real-world motion artifacts, outperforming conventional filtering and existing neural models. Our method can effectively restore PPG signals while maintaining HR accuracy, highlighting the complementary roles of SI-SDR loss and HR-guided supervision. These results demonstrate the potential of our approach for practical deployment in wearable healthcare systems.

Abstract:Photoplethysmography (PPG) is widely used in wearable health monitoring, but its reliability is often degraded by noise and motion artifacts, limiting downstream applications such as heart rate (HR) estimation. This paper presents a deep learning framework for PPG denoising with an emphasis on preserving physiological information. In this framework, we propose DPNet, a Mamba-based denoising backbone designed for effective temporal modeling. To further enhance denoising performance, the framework also incorporates a scale-invariant signal-to-distortion ratio (SI-SDR) loss to promote waveform fidelity and an auxiliary HR predictor (HRP) that provides physiological consistency through HR-based supervision. Experiments on the BIDMC dataset show that our method achieves strong robustness against both synthetic noise and real-world motion artifacts, outperforming conventional filtering and existing neural models. Our method can effectively restore PPG signals while maintaining HR accuracy, highlighting the complementary roles of SI-SDR loss and HR-guided supervision. These results demonstrate the potential of our approach for practical deployment in wearable healthcare systems.

Machine Learning (cs.LG); Signal Processing (eess.SP)

arXiv:2510.11058 [cs.LG]

(or arXiv:2510.11058v2 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2510.11058 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 251 words

Related coverage