Skip to content
Off-topic for aiqbench

Off-topic for aiqbench

This story was gathered from a source we follow but falls outside AI and quantum coverage, so there is no aiqbench take for it.

HULFSynth : An INR based Super-Resolution and Ultra Low-Field MRI Synthesis via Contrast factor estimation

arXiv2 min read

arXiv:2511.14897v2 Announce Type: replace-cross Abstract: We present an unsupervised single image bidirectional Magnetic Resonance Image (MRI) synthesizer that synthesizes an Ultra-Low Field (ULF) like image from a High-Field (HF) magnitude image and vice-versa. Unlike existing MRI synthesis models, our approach is inspired by the physics that drives contrast changes between HF and ULF MRIs. Our forward model simulates a HF to ULF transformation by estimating the tissue-type Signal-to-Noise ratio (SNR) values based on target contrast values. For the Super-Resolution task, we used an Implicit Neural Representation (INR) network to synthesize HF image by simultaneously predicting tissue-type segmentations and image intensity without observed HF data. The proposed method is evaluated using synthetic ULF-like data from generated from standard 3T T$_1$-weighted images for qualitative assessments and paired 3T-64mT T$_1$-weighted images for validation experiments. WM-GM contrast improved by 52% in synthetic ULF-like images and 37% in 64mT images. Sensitivity experiments demonstrated the robustness of our forward model to variations in target contrast, noise and initial seeding.

Abstract:We present an unsupervised single image bidirectional Magnetic Resonance Image (MRI) synthesizer that synthesizes an Ultra-Low Field (ULF) like image from a High-Field (HF) magnitude image and vice-versa. Unlike existing MRI synthesis models, our approach is inspired by the physics that drives contrast changes between HF and ULF MRIs. Our forward model simulates a HF to ULF transformation by estimating the tissue-type Signal-to-Noise ratio (SNR) values based on target contrast values. For the Super-Resolution task, we used an Implicit Neural Representation (INR) network to synthesize HF image by simultaneously predicting tissue-type segmentations and image intensity without observed HF data. The proposed method is evaluated using synthetic ULF-like data from generated from standard 3T T$_1$-weighted images for qualitative assessments and paired 3T-64mT T$_1$-weighted images for validation experiments. WM-GM contrast improved by 52% in synthetic ULF-like images and 37% in 64mT images. Sensitivity experiments demonstrated the robustness of our forward model to variations in target contrast, noise and initial seeding.

Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG)

arXiv:2511.14897 [cs.CV]

(or arXiv:2511.14897v2 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2511.14897 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 256 words

Related coverage