În afara temei aiqbench
Această știre a fost preluată de la o sursă pe care o urmărim, dar nu ține de domeniul AI sau cuantic, așa că nu există o perspectivă aiqbench pentru ea.
HULFSynth : An INR based Super-Resolution and Ultra Low-Field MRI Synthesis via Contrast factor estimation
arXiv:2511.14897v2 Announce Type: replace-cross Abstract: We present an unsupervised single image bidirectional Magnetic Resonance Image (MRI) synthesizer that synthesizes an Ultra-Low Field (ULF) like image from a High-Field (HF) magnitude image and vice-versa. Unlike existing MRI synthesis models, our approach is inspired by the physics that drives contrast changes between HF and ULF MRIs. Our forward model simulates a HF to ULF transformation by estimating the tissue-type Signal-to-Noise ratio (SNR) values based on target contrast values. For the Super-Resolution task, we used an Implicit Neural Representation (INR) network to synthesize HF image by simultaneously predicting tissue-type segmentations and image intensity without observed HF data. The proposed method is evaluated using synthetic ULF-like data from generated from standard 3T T$_1$-weighted images for qualitative assessments and paired 3T-64mT T$_1$-weighted images for validation experiments. WM-GM contrast improved by 52% in synthetic ULF-like images and 37% in 64mT images. Sensitivity experiments demonstrated the robustness of our forward model to variations in target contrast, noise and initial seeding.
Abstract:We present an unsupervised single image bidirectional Magnetic Resonance Image (MRI) synthesizer that synthesizes an Ultra-Low Field (ULF) like image from a High-Field (HF) magnitude image and vice-versa. Unlike existing MRI synthesis models, our approach is inspired by the physics that drives contrast changes between HF and ULF MRIs. Our forward model simulates a HF to ULF transformation by estimating the tissue-type Signal-to-Noise ratio (SNR) values based on target contrast values. For the Super-Resolution task, we used an Implicit Neural Representation (INR) network to synthesize HF image by simultaneously predicting tissue-type segmentations and image intensity without observed HF data. The proposed method is evaluated using synthetic ULF-like data from generated from standard 3T T$_1$-weighted images for qualitative assessments and paired 3T-64mT T$_1$-weighted images for validation experiments. WM-GM contrast improved by 52% in synthetic ULF-like images and 37% in 64mT images. Sensitivity experiments demonstrated the robustness of our forward model to variations in target contrast, noise and initial seeding.
Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG)
arXiv:2511.14897 [cs.CV]
(or arXiv:2511.14897v2 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2511.14897 Focus to learn more arXiv-issued DOI via DataCite
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 256 cuvinte
Subiecte conexe
Does preservation make sense before we know how to revive?
LessWrong · 15 iun. 2026

NVIDIA GTC Taipei at COMPUTEX: Live Updates on What’s Next in AI
NVIDIA · 21 mai 2026

[AINews] Reality Checks on AI News (Yegge shuts down Gas Town, Databricks’ +60% Astra cost)
Latent Space · 17 sept. 2026

Q-BIOMED Secures £902K to Expand Healthcare Quantum Sensing
Quantum Zeitgeist · 31 mai 2026