aiqbench analysis
This paper argues that a single F1 score hides two different failure modes in LLM question answering over radiology reports: unsupported answers and unnecessary abstentions. Across 13 models, similar F1 scores masked more than twofold differences in false-answer rate, and adding an unanswerable example mainly changed when models abstained, not how well they extracted. For readers evaluating LLMs in clinical or other high-stakes settings, the practical takeaway is to report answerability and extraction separately rather than relying on F1 alone.
Dissociating Answerability from Extraction in LLM Question Answering over Radiology Reports
arXiv:2610.17576v1 Announce Type: cross Abstract: Answering questions from radiology reports involves two decisions: whether the report contains an answer and which span gives it. A false answer presents an unsupported claim as fact; an over-abstention hides what the report says. Yet RadQA results are reported as a single F1 that merges both. We propose an evaluation method that separates them, reporting false-answer and over-abstention rates beside F1 and splitting F1 changes into extraction and answerability terms. We apply it to 13 LLMs on the RadQA test set, zero-shot and with three cumulative demonstration sets, the last adding an unanswerable example. Models with similar F1 differed more than twofold in false-answer rate. The unanswerable example changed when models answered, not how well they extracted: 12 of 13 models abstained more often, and three-quarters of the answers they withdrew had F1 $\geq$ 0.5. Within models, false answers showed no clear association with extraction quality, but acting on the decision itself helped: keeping an answer only when enough other models also answered lowered the zero-shot false-answer rate by 4 points without a detectable F1 change. Because the two decisions can change independently, we suggest radiology QA evaluations report them separately, not through F1 alone.
Abstract:Answering questions from radiology reports involves two decisions: whether the report contains an answer and which span gives it. A false answer presents an unsupported claim as fact; an over-abstention hides what the report says. Yet RadQA results are reported as a single F1 that merges both. We propose an evaluation method that separates them, reporting false-answer and over-abstention rates beside F1 and splitting F1 changes into extraction and answerability terms. We apply it to 13 LLMs on the RadQA test set, zero-shot and with three cumulative demonstration sets, the last adding an unanswerable example. Models with similar F1 differed more than twofold in false-answer rate. The unanswerable example changed when models answered, not how well they extracted: 12 of 13 models abstained more often, and three-quarters of the answers they withdrew had F1 $\geq$ 0.5. Within models, false answers showed no clear association with extraction quality, but acting on the decision itself helped: keeping an answer only when enough other models also answered lowered the zero-shot false-answer rate by 4 points without a detectable F1 change. Because the two decisions can change independently, we suggest radiology QA evaluations report them separately, not through F1 alone.
Computation and Language (cs.CL); Artificial Intelligence (cs.AI); Machine Learning (cs.LG)
arXiv:2610.17576 [cs.CL]
(or arXiv:2610.17576v1 [cs.CL] for this version)
https://doi.org/10.48550/arXiv.2610.17576 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 297 words
Related coverage

Biomedical Imaging's Real Bottleneck Is the Data, Not the Model
Databricks · Oct 8, 2026
Problems of Proliferation
LessWrong · Sep 29, 2026
ReportQA: QA-Based Radiology Report Evaluation
arXiv · Jun 17, 2026
Prototype-Based Knowledge Guidance for Fine-Grained Structured Radiology Reporting
arXiv · Oct 8, 2026