Skip to content
aiqbench takeAI Products

aiqbench analysis

ReportQA introduces an LLM-based evaluation framework that shifts radiology report assessment from simple entity presence to clinically relevant question-answering accuracy. By using large language models as judge models within a structured knowledge tree, this approach addresses the limitations of traditional metrics in capturing fine-grained clinical representations without relying heavily on manual annotations for every new attribute. This method offers a more robust benchmark for automated report generation systems that must align with actual radiologist decision-making processes.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

ReportQA: QA-Based Radiology Report Evaluation

arXiv3 min read

arXiv:2606.15037v1 Announce Type: new Abstract: Radiology report evaluation is essential for advancing automated report generation. Natural language generation metrics have limited clinical relevance. Clinical efficacy (CE) metrics evaluate important medical findings, but focus mainly on presence and cover only a limited set of entities. Due to heavy reliance on manual annotations, it is difficult for CE metrics to extend clinical entities or attributes. In clinical practice, radiology reports serve as a medium for information transfer. Clinicians use them to perform downstream diagnostic tasks without directly inspecting images. Based on this insight, we propose ReportQA, a clinical-related and flexible radiology report evaluation framework, supporting detailed quantitative analysis of radiology report generation systems. We first collect datasets covering multiple imaging modalities and anatomical regions. We then construct knowledge trees of clinical entities and attributes with radiologist guidance, and use large language models (LLMs) to extract structured information from raw reports. Next, we generate QA pairs from predefined templates and apply quality control through self-filtering and report-based filtering. During evaluation, the report is treated as context, and an LLM acts as a judge model to answer the QA pairs. Based on the resulting QA accuracy, we introduce QAScore metric. Compared with existing metrics, QAScore shows better alignment with radiologist judgments. Experiments on multiple state-of-the-art vision-language models reveal that current report-based inference paradigms struggle to learn fine-grained clinical representations and exhibit strong negative prior biases. In contrast, question-driven inference provides a more effective alternative. For reproducibility and extensibility, we release the knowledge trees, structured reports, and QA pairs, along with the pipeline code for QA construction and evaluation.

Abstract:Radiology report evaluation is essential for advancing automated report generation. Natural language generation metrics have limited clinical relevance. Clinical efficacy (CE) metrics evaluate important medical findings, but focus mainly on presence and cover only a limited set of entities. Due to heavy reliance on manual annotations, it is difficult for CE metrics to extend clinical entities or attributes. In clinical practice, radiology reports serve as a medium for information transfer. Clinicians use them to perform downstream diagnostic tasks without directly inspecting images. Based on this insight, we propose ReportQA, a clinical-related and flexible radiology report evaluation framework, supporting detailed quantitative analysis of radiology report generation systems. We first collect datasets covering multiple imaging modalities and anatomical regions. We then construct knowledge trees of clinical entities and attributes with radiologist guidance, and use large language models (LLMs) to extract structured information from raw reports. Next, we generate QA pairs from predefined templates and apply quality control through self-filtering and report-based filtering. During evaluation, the report is treated as context, and an LLM acts as a judge model to answer the QA pairs. Based on the resulting QA accuracy, we introduce QAScore metric. Compared with existing metrics, QAScore shows better alignment with radiologist judgments. Experiments on multiple state-of-the-art vision-language models reveal that current report-based inference paradigms struggle to learn fine-grained clinical representations and exhibit strong negative prior biases. In contrast, question-driven inference provides a more effective alternative. For reproducibility and extensibility, we release the knowledge trees, structured reports, and QA pairs, along with the pipeline code for QA construction and evaluation.

Computation and Language (cs.CL); Computer Vision and Pattern Recognition (cs.CV)

arXiv:2606.15037 [cs.CL]

(or arXiv:2606.15037v1 [cs.CL] for this version)

https://doi.org/10.48550/arXiv.2606.15037 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 360 words

Related coverage