Skip to content
aiqbench takeAI Research

aiqbench analysis

This study evaluates the efficacy of cross-anatomy transfer learning versus sparse interpolation for digital twin surrogates in fluid-structure interaction simulations. The results indicate that simple interpolation methods significantly outperform zero-shot transfer across independent anatomies, suggesting current geometric priors offer limited generalization without extensive adaptation. While this represents a foundational step toward measurement-linked digital twins, the authors clarify that larger cohorts and physics-informed learning remain necessary for clinical viability.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Cross-Anatomy Transfer Versus Sparse Interpolation in Digital-Twin-Oriented Aortic Fluid-Structure Interaction Surrogates

arXiv3 min read

arXiv:2609.16322v1 Announce Type: new Abstract: Surrogate credibility for fluid-structure interac- tion (FSI) requires distinguishing transfer across independent anatomies from interpolation within an already sampled surface. Four de-identified human aortic models from the Vascular Model Repository were reconstructed into separate lumen and nominal 1.5-mm wall domains and analyzed under matched first-cycle two-way FSI. A geometry-only LightGBM prior, selected by leave-one-anatomy-out development on three anatomies, was zero-shot evaluated on a fourth, then probed with a post-zero- shot sparse field-completion case study over six targets. Zero-shot transfer was poor across all targets. At a five-percent anchor level (203 anchors, 3,852 evaluation nodes), prior-plus-adaptation reached an oscillatory shear index (OSI) R2 of 0.603. However, same-anchor controls tuned only on the three development anatomies were stronger for several outcomes: inverse-distance weighting reached R2 = 0.829 (OSI), 0.617 (peak von Mises stress), 0.676 (mean stress); radial basis function interpolation reached 0.917, 0.714, 0.778. Sparse within-anatomy labels thus support field completion, but this four-anatomy cohort gives no evidence the cross-anatomy prior adds value beyond direct interpolation. We frame this as a first computational stage toward a measurement-linked digital twin: the surrogate/update layer is evaluated here, while larger cohorts, converged FSI, measurable patient-side inputs, and physics-informed learning remain future work, not a claim of a complete clinical twin. Our code, data and computation files are available at https://github. com/ali-nourbakhsh2005/Aortic-FSI-Sparse-Field-Completion

Abstract:Surrogate credibility for fluid-structure interac- tion (FSI) requires distinguishing transfer across independent anatomies from interpolation within an already sampled surface. Four de-identified human aortic models from the Vascular Model Repository were reconstructed into separate lumen and nominal 1.5-mm wall domains and analyzed under matched first-cycle two-way FSI. A geometry-only LightGBM prior, selected by leave-one-anatomy-out development on three anatomies, was zero-shot evaluated on a fourth, then probed with a post-zero- shot sparse field-completion case study over six targets. Zero-shot transfer was poor across all targets. At a five-percent anchor level (203 anchors, 3,852 evaluation nodes), prior-plus-adaptation reached an oscillatory shear index (OSI) R2 of 0.603. However, same-anchor controls tuned only on the three development anatomies were stronger for several outcomes: inverse-distance weighting reached R2 = 0.829 (OSI), 0.617 (peak von Mises stress), 0.676 (mean stress); radial basis function interpolation reached 0.917, 0.714, 0.778. Sparse within-anatomy labels thus support field completion, but this four-anatomy cohort gives no evidence the cross-anatomy prior adds value beyond direct interpolation. We frame this as a first computational stage toward a measurement-linked digital twin: the surrogate/update layer is evaluated here, while larger cohorts, converged FSI, measurable patient-side inputs, and physics-informed learning remain future work, not a claim of a complete clinical twin. Our code, data and computation files are available at https://github. com/ali-nourbakhsh2005/Aortic-FSI-Sparse-Field-Completion

Artificial Intelligence (cs.AI); Machine Learning (cs.LG)

arXiv:2609.16322 [cs.AI]

(or arXiv:2609.16322v1 [cs.AI] for this version)

https://doi.org/10.48550/arXiv.2609.16322 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 313 words

Related coverage