aiqbench analysis
This study applies a pretrained CT foundation model to create an uncertainty-guided digital twin for forecasting anatomical changes during head and neck proton therapy. By predicting daily anatomy before treatment sessions, the framework enables online adaptive planning that matches the clinical quality of traditional offline replanning, effectively reducing high-dose exposure to critical structures like the spinal cord. The work demonstrates a practical integration of generative AI into precision oncology workflows to address the limitations of reactive treatment adjustments.
An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility Study
arXiv:2609.39010v1 Announce Type: cross Abstract: Objective: Head and neck (HN) proton therapy spans six to seven weeks of anatomical change, while offline replanning takes about a week. We present an uncertainty-guided digital twin (UGDT) framework that forecasts treatment-day anatomy before treatment and evaluate whether it generates online adaptive proton therapy (APT) plans of clinical quality. Approach: A library of 302 longitudinal deformations from 88 previously treated HN patients was transported onto each new patient's treatment planning CT (TPCT) using two-step multi-atlas deformable image registration (DIR) built on a pretrained CT foundation model, generating about 284 predicted CTs (pdCTs) with contours per patient. Dispersion of propagated clinical target volume (CTV) contours defined a patient-specific robust margin. In ten patients, the quality assurance CT (QACT) triggering a replan represented treatment-day anatomy, and the physician-approved replan was the baseline. The pdCT most similar to the QACT (pdCT-H) and one from the lowest quartile (pdCT-L) were planned to within about 5% of baseline plan quality, forward-calculated on the QACT, and reoptimized to generate online APT plans. Main results: pdCT plans scored within -0.7% (pdCT-H) and -1.0% (pdCT-L) of baseline. Forward calculation on QACT reduced high-dose CTV D98% to 88.3% and 85.5%. After online reoptimization, D98% recovered to 98.3 +/- 0.3% and 98.2 +/- 0.3%, versus 98.5 +/- 0.4% at baseline. Spinal cord and brainstem doses remained below tolerance, and plan quality scores were within -1.1% (p = 0.19) and -1.7% (p = 0.01) of baseline. Significance: UGDT generated online APT plans comparable in quality to physician-approved offline replans using anatomy forecast before treatment, enabling a transition from reactive offline replanning toward anticipatory online adaptation.
Authors:Yizhou Wu, Ryan J. Sanford, Huiqiao Xie, Jie Ding, Shupeng Chen, Tung-Ho Wu, Ping-Hsiu Wu, Justin Roper, Jun Zhou, Minglei Kang, Bill Stokes, Sibo Tian, David S. Yu, Xiaofeng Yang, Chih-Wei Chang
Abstract:Objective: Head and neck (HN) proton therapy spans six to seven weeks of anatomical change, while offline replanning takes about a week. We present an uncertainty-guided digital twin (UGDT) framework that forecasts treatment-day anatomy before treatment and evaluate whether it generates online adaptive proton therapy (APT) plans of clinical quality. Approach: A library of 302 longitudinal deformations from 88 previously treated HN patients was transported onto each new patient's treatment planning CT (TPCT) using two-step multi-atlas deformable image registration (DIR) built on a pretrained CT foundation model, generating about 284 predicted CTs (pdCTs) with contours per patient. Dispersion of propagated clinical target volume (CTV) contours defined a patient-specific robust margin. In ten patients, the quality assurance CT (QACT) triggering a replan represented treatment-day anatomy, and the physician-approved replan was the baseline. The pdCT most similar to the QACT (pdCT-H) and one from the lowest quartile (pdCT-L) were planned to within about 5% of baseline plan quality, forward-calculated on the QACT, and reoptimized to generate online APT plans. Main results: pdCT plans scored within -0.7% (pdCT-H) and -1.0% (pdCT-L) of baseline. Forward calculation on QACT reduced high-dose CTV D98% to 88.3% and 85.5%. After online reoptimization, D98% recovered to 98.3 +/- 0.3% and 98.2 +/- 0.3%, versus 98.5 +/- 0.4% at baseline. Spinal cord and brainstem doses remained below tolerance, and plan quality scores were within -1.1% (p = 0.19) and -1.7% (p = 0.01) of baseline. Significance: UGDT generated online APT plans comparable in quality to physician-approved offline replans using anatomy forecast before treatment, enabling a transition from reactive offline replanning toward anticipatory online adaptation.
Medical Physics (physics.med-ph); Artificial Intelligence (cs.AI)
arXiv:2609.39010 [physics.med-ph]
(or arXiv:2609.39010v1 [physics.med-ph] for this version)
https://doi.org/10.48550/arXiv.2609.39010 arXiv-issued DOI via DataCite (pending registration)
Full text under the publisher's open licence · 318 words
Related coverage
A Continual Validation, Updating, and Decision-Making Framework for Self-Adaptive Digital Twins via Robust Model Predictive Control: A Case Study in Additive Manufacturing
arXiv · Jul 21, 2026
Anticipatory Digital Twins for Online Head-and-Neck Adaptive Proton Therapy via Foundation-Model Registration
arXiv · Aug 5, 2026

Jefferson Lab’s AI spots trouble in fusion reactors
Quantum Zeitgeist · Aug 13, 2026

Digital States 2026: AI Moves From Experiment to Infrastructure
govtech.com · Sep 24, 2026