Skip to content
aiqbench takeMachine Learning

aiqbench analysis

This research introduces isotonic Bellman calibration, a model-agnostic post-processing technique designed to correct occupancy-balance violations in offline reinforcement learning without discarding ranking information. By establishing finite-sample guarantees and KL oracle inequalities, the method ensures that calibrated estimates perform nearly as well as optimal monotone corrections while addressing limitations in existing estimators like minimax or primal-dual approaches.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Bellman Calibration for Marginalized Importance Weighting in Offline Reinforcement Learning

arXiv3 min read

arXiv:2608.24858v1 Announce Type: new Abstract: Marginalized importance weighting evaluates a target policy by reweighting offline state-action samples with its discounted occupancy ratio, characterized by an adjoint Bellman equation. Existing minimax, primal-dual, and fitted fixed-point estimators can leave residual occupancy-balance violations because of function-class approximation, regularization, or incomplete optimization. These violations are difficult to diagnose and reduce because the objectives generally lack a direct supervised validation loss for hyperparameter tuning, model selection, and early stopping. We introduce isotonic Bellman calibration, a one-dimensional, model-agnostic post-processing method that reduces these violations while preserving the ranking information in any initial occupancy-ratio estimate. The method corrects the estimate's scale and shape by applying fitted occupancy-ratio evaluation (FORE) over a one-dimensional class of nondecreasing transformations. We characterize Bellman calibration as a conditional fixed-point property equivalent to occupancy-balance against every test function of the calibrated ratio. More generally, we derive a calibration-refinement bound showing that any fitted ratio with small calibration error performs nearly as well as the best post-processing based on its fitted values. For isotonic Bellman calibration, we establish finite-sample calibration guarantees and a KL oracle inequality relative to the best monotone transformation of the initial estimate. Consequently, isotonic Bellman calibration achieves small calibration error and KL risk within statistical error of the best monotone correction, with guarantees for downstream target-occupancy functionals, including policy-value estimation.

Abstract:Marginalized importance weighting evaluates a target policy by reweighting offline state-action samples with its discounted occupancy ratio, characterized by an adjoint Bellman equation. Existing minimax, primal-dual, and fitted fixed-point estimators can leave residual occupancy-balance violations because of function-class approximation, regularization, or incomplete optimization. These violations are difficult to diagnose and reduce because the objectives generally lack a direct supervised validation loss for hyperparameter tuning, model selection, and early stopping. We introduce isotonic Bellman calibration, a one-dimensional, model-agnostic post-processing method that reduces these violations while preserving the ranking information in any initial occupancy-ratio estimate. The method corrects the estimate's scale and shape by applying fitted occupancy-ratio evaluation (FORE) over a one-dimensional class of nondecreasing transformations. We characterize Bellman calibration as a conditional fixed-point property equivalent to occupancy-balance against every test function of the calibrated ratio. More generally, we derive a calibration-refinement bound showing that any fitted ratio with small calibration error performs nearly as well as the best post-processing based on its fitted values. For isotonic Bellman calibration, we establish finite-sample calibration guarantees and a KL oracle inequality relative to the best monotone transformation of the initial estimate. Consequently, isotonic Bellman calibration achieves small calibration error and KL risk within statistical error of the best monotone correction, with guarantees for downstream target-occupancy functionals, including policy-value estimation.

Machine Learning (cs.LG); Machine Learning (stat.ML)

arXiv:2608.24858 [cs.LG]

(or arXiv:2608.24858v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2608.24858 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 312 words

Related coverage