Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchCercetare AI

analiza aiqbench

This research introduces FHRFormer, a masked transformer framework designed to reconstruct missing fetal heart rate signals and enable forecasting for prenatal risk assessment. By addressing signal dropout issues in wearable monitors through advanced inpainting, the method aims to improve the reliability of automated AI analysis for detecting adverse fetal conditions. The work represents a significant step toward more robust clinical decision-support tools in obstetrics.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

FHRFormer: A Self-Supervised Masked Transformer Framework for Fetal Heart Rate Time-Series Inpainting and Forecasting

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2605.29695v2 Announce Type: replace-cross Abstract: Approximately 10% of newborns require assistance to initiate breathing at birth, and around 5% need ventilation support. Fetal heart rate (FHR) monitoring plays a crucial role in assessing fetal well-being during prenatal care, enabling the detection of abnormal patterns and supporting timely obstetric interventions to mitigate fetal risks during labor. Applying artificial intelligence (AI) methods to analyze large datasets of continuous FHR monitoring episodes with diverse outcomes may offer novel insights into predicting the risk of needing breathing assistance or interventions. Recent advances in wearable FHR monitors have enabled continuous fetal monitoring without compromising maternal mobility. However, sensor displacement during maternal movement, as well as changes in fetal or maternal position, often lead to signal dropout, resulting in gaps in recorded FHR data. Such missing data limits the extraction of meaningful insights and complicates automated (AI-based) analysis. Traditional approaches to handling missing data, such as simple interpolation techniques, often fail to preserve the spectral characteristics of the signals. In this paper, we propose a masked transformer-based autoencoder approach to reconstruct missing FHR signals by capturing both local temporal and frequency components of the data. The proposed method demonstrates robustness across varying durations of missing data and can be used for signal inpainting and forecasting. The proposed approach can be applied retrospectively to research datasets to support the development of AI-based risk algorithms. In the future, the proposed method could be integrated into wearable FHR monitoring devices to achieve earlier and more robust risk detection.

Abstract:Approximately 10% of newborns require assistance to initiate breathing at birth, and around 5% need ventilation support. Fetal heart rate (FHR) monitoring plays a crucial role in assessing fetal well-being during prenatal care, enabling the detection of abnormal patterns and supporting timely obstetric interventions to mitigate fetal risks during labor. Applying artificial intelligence (AI) methods to analyze large datasets of continuous FHR monitoring episodes with diverse outcomes may offer novel insights into predicting the risk of needing breathing assistance or interventions. Recent advances in wearable FHR monitors have enabled continuous fetal monitoring without compromising maternal mobility. However, sensor displacement during maternal movement, as well as changes in fetal or maternal position, often lead to signal dropout, resulting in gaps in recorded FHR data. Such missing data limits the extraction of meaningful insights and complicates automated (AI-based) analysis. Traditional approaches to handling missing data, such as simple interpolation techniques, often fail to preserve the spectral characteristics of the signals. In this paper, we propose a masked transformer-based autoencoder approach to reconstruct missing FHR signals by capturing both local temporal and frequency components of the data. The proposed method demonstrates robustness across varying durations of missing data and can be used for signal inpainting and forecasting. The proposed approach can be applied retrospectively to research datasets to support the development of AI-based risk algorithms. In the future, the proposed method could be integrated into wearable FHR monitoring devices to achieve earlier and more robust risk detection.

Artificial Intelligence (cs.AI); Computational Engineering, Finance, and Science (cs.CE); Machine Learning (cs.LG); Probability (math.PR)

arXiv:2605.29695 [cs.AI]

(or arXiv:2605.29695v2 [cs.AI] for this version)

https://doi.org/10.48550/arXiv.2605.29695 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 347 cuvinte

Subiecte conexe