This research advances self-supervised machine learning by leveraging Conformer-based Masked Autoencoders to extract high-fidelity features from unlabeled EEG and HRV data for neonatal HIE classification. The approach demonstrates significant transferability, achieving state-of-the-art performance on downstream diagnostic tasks while reducing reliance on large annotated datasets.
Neonatal Hypoxic-ischaemic Encephalopathy Classification from the EEG and HRV Signals Using a Conformer based Masked Autoencoder
arXiv:2607.23554v1 Announce Type: cross Abstract: In this paper, we propose the MAEConformer, a novel self-supervised learning framework that combines the Conformer architecture with the Masked Autoencoder (MAE) paradigm for large-scale representation learning from unlabelled electroencephalography (EEG) and heart rate variability (HRV) signals. By integrating convolutional operations with Transformer-based self-attention, MAEConformer effectively captures both local temporal patterns and long-range contextual dependencies in physiological time series. To enhance reconstruction fidelity and representation quality, a multi-resolution short-time Fourier transform (MR-STFT) loss is incorporated alongside the reconstruction objective, enabling the model to jointly learn temporal and spectral characteristics across multiple scales. Modality-specific EEG and HRV MAEConformer models were pretrained on 6,030h and 4,868h of unlabelled recordings, respectively, and subsequently transferred to expert-annotated downstream tasks. Experimental results demonstrate that the learned representations provide strong transferability and data efficiency. In EEG-based hypoxic ischemic encephalopathy (HIE) severity classification, the pretrained MAE-EEG model achieved test AUCs of 97.19% and 96.56% for binary and four-class classification tasks, respectively, outperforming a range of state-of-the-art supervised and self-supervised baselines. On the HRV-based HIE severity classification task, MAE-HRV achieved a test AUC of 82.42%, surpassing both self-supervised Transformer-based and supervised convolutional baselines. These findings demonstrate the effectiveness of MAEConformer for learning robust and transferable representations across multiple physiological modalities.
Abstract:In this paper, we propose the MAEConformer, a novel self-supervised learning framework that combines the Conformer architecture with the Masked Autoencoder (MAE) paradigm for large-scale representation learning from unlabelled electroencephalography (EEG) and heart rate variability (HRV) signals. By integrating convolutional operations with Transformer-based self-attention, MAEConformer effectively captures both local temporal patterns and long-range contextual dependencies in physiological time series. To enhance reconstruction fidelity and representation quality, a multi-resolution short-time Fourier transform (MR-STFT) loss is incorporated alongside the reconstruction objective, enabling the model to jointly learn temporal and spectral characteristics across multiple scales. Modality-specific EEG and HRV MAEConformer models were pretrained on 6,030h and 4,868h of unlabelled recordings, respectively, and subsequently transferred to expert-annotated downstream tasks. Experimental results demonstrate that the learned representations provide strong transferability and data efficiency. In EEG-based hypoxic ischemic encephalopathy (HIE) severity classification, the pretrained MAE-EEG model achieved test AUCs of 97.19% and 96.56% for binary and four-class classification tasks, respectively, outperforming a range of state-of-the-art supervised and self-supervised baselines. On the HRV-based HIE severity classification task, MAE-HRV achieved a test AUC of 82.42%, surpassing both self-supervised Transformer-based and supervised convolutional baselines. These findings demonstrate the effectiveness of MAEConformer for learning robust and transferable representations across multiple physiological modalities.
Machine Learning (cs.LG); Artificial Intelligence (cs.AI); Signal Processing (eess.SP)
arXiv:2607.23554 [cs.LG]
(or arXiv:2607.23554v1 [cs.LG] for this version)
https://doi.org/10.48550/arXiv.2607.23554 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 302 cuvinte
Subiecte conexe
Expert-level detection of low-voltage intervals in EEG as a robust biomarker of neonatal encephalopathy
arXiv · 12 oct. 2026
Large Language Models for Structured Clinical Data Analysis: Dual-Agent Grounding and Validation
arXiv · 29 sept. 2026
Base Models Can Detect Hidden Intentions that Prompted Classifiers Miss
LessWrong · 12 oct. 2026

Article: Governing AI in the Cloud: A Practical Guide for Architects
InfoQ · 15 iun. 2026