Skip to content
Off-topic for aiqbench

Off-topic for aiqbench

This story was gathered from a source we follow but falls outside AI and quantum coverage, so there is no aiqbench take for it.

Zeptojoule Microwave Calorimetry with Nanosecond Recovery in Graphene

arXiv2 min read

arXiv:2610.33414v1 Announce Type: cross Abstract: Graphene calorimeters are predicted to combine extreme energy sensitivity with rapid thermal recovery, yet experiments remain far from ideal estimates. Here, we directly calibrate a graphene Josephson-junction microwave calorimeter using nanosecond pulses and independently determine the thermal parameters of the same operating device. At 110 mK, calibrated pulse measurements yield a characteristic switching-energy scale of 18.1 meV (2.90 zJ), while time-resolved two-pulse thermometry gives an intrinsic relaxation time of 19.5 ns. Pulse-width-dependent calorimetry and bolometric thermometry show that the electronic heat capacity is 12.4 times and the electron-phonon coupling is approximately 50 times larger than ideal estimates. A thermal model using these measured parameters predicts 21.2 meV, quantitatively reproducing the observed switching response. These results identify the microscopic origin of the sensitivity gap in graphene calorimeters and establish a self-consistent calibration framework for ultrafast nanoscale thermal detectors.

Authors:Seunghan Lee, Woochan Jung, Jayeon Kim, Dongsung T. Park, Seong Jang, Seongeun Jeon, Kenji Watanabe, Takashi Taniguchi, Jong-Chul Park, Philip Kim, Kin Chung Fong, Gil-Ho Lee

Abstract:Graphene calorimeters are predicted to combine extreme energy sensitivity with rapid thermal recovery, yet experiments remain far from ideal estimates. Here, we directly calibrate a graphene Josephson-junction microwave calorimeter using nanosecond pulses and independently determine the thermal parameters of the same operating device. At 110 mK, calibrated pulse measurements yield a characteristic switching-energy scale of 18.1 meV (2.90 zJ), while time-resolved two-pulse thermometry gives an intrinsic relaxation time of 19.5 ns. Pulse-width-dependent calorimetry and bolometric thermometry show that the electronic heat capacity is 12.4 times and the electron-phonon coupling is approximately 50 times larger than ideal estimates. A thermal model using these measured parameters predicts 21.2 meV, quantitatively reproducing the observed switching response. These results identify the microscopic origin of the sensitivity gap in graphene calorimeters and establish a self-consistent calibration framework for ultrafast nanoscale thermal detectors.

Mesoscale and Nanoscale Physics (cond-mat.mes-hall); Quantum Physics (quant-ph)

arXiv:2610.33414 [cond-mat.mes-hall]

(or arXiv:2610.33414v1 [cond-mat.mes-hall] for this version)

https://doi.org/10.48550/arXiv.2610.33414 arXiv-issued DOI via DataCite (pending registration)

Full text under the publisher's open licence · 186 words