This research applies deep learning to assess signal quality in ambulatory ECGs, leveraging a novel database enriched with physical and patient-reported context data. The study validates the model's stability across standard benchmarks like MIT-BIT and PhysioNet, offering a method to investigate complex noise sources through contextual analysis. While the application is medical, the core contribution lies in advancing signal processing techniques via machine learning for wearable health monitoring.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Wearable ECG Quality Assessment: A Deep Learning and Ambulatory Context-Awareness Approach

arXiv1 min read

arXiv:2609.29396v1 Announce Type: new Abstract: This paper presents and evaluates a Deep Learning-based (DL-based) Signal Quality Assessment (SQA) model to distinguish between clean and noisy ambulatory Electrocardiograms (ECG). The model is trained on Copenhagen Center for Health Technology-Contextualized Arrhythmia Database (CACHET-CADB), which, to the best of our knowledge, is the first ambulatory ECG database with both physical and patient-reported contextual data. The model shows stable performance on different databases such as MIT-databases and the latest PyhsioNet/Cinc Challenge 2021 databases. Subsequently, the paper demonstrates how complicated ECG noise can be investigated by the SQA model and the physical contextual data.

Abstract:This paper presents and evaluates a Deep Learning-based (DL-based) Signal Quality Assessment (SQA) model to distinguish between clean and noisy ambulatory Electrocardiograms (ECG). The model is trained on Copenhagen Center for Health Technology-Contextualized Arrhythmia Database (CACHET-CADB), which, to the best of our knowledge, is the first ambulatory ECG database with both physical and patient-reported contextual data. The model shows stable performance on different databases such as MIT-databases and the latest PyhsioNet/Cinc Challenge 2021 databases. Subsequently, the paper demonstrates how complicated ECG noise can be investigated by the SQA model and the physical contextual data.

Artificial Intelligence (cs.AI); Signal Processing (eess.SP)

arXiv:2609.29396 [cs.AI]

(or arXiv:2609.29396v1 [cs.AI] for this version)

https://doi.org/10.48550/arXiv.2609.29396 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 191 words

Related coverage