Skip to content
aiqbench takeAI Research

aiqbench analysis

This research establishes a critical benchmark for automated dataset quality assurance using unsupervised anomaly detection to safeguard high-risk medical AI systems against corrupted or inconsistent MRI data. By evaluating multiple methods across diverse institutional datasets, the study highlights that while far-out-of-distribution samples are reliably detected, near-OOD cases and external normal data require domain-specific adaptation to prevent generalization failures. These findings provide essential guidance for building robust pipelines in healthcare applications where silent data threats directly impact patient safety.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Unsupervised Anomaly Detection for Image Dataset Quality Assurance in Multi-Center Breast MRI

arXiv3 min read

arXiv:2608.16725v1 Announce Type: cross Abstract: Corrupted, inconsistent, or anomalous data silently threatens the safety and reliability of medical AI. Despite growing regulatory recognition of dataset quality assurance (QA) for high-risk medical AI, scalable automated detection remains underdeveloped. We employ unsupervised anomaly detection (AD) and out-of-distribution (OOD) detection as an automated dataset QA mechanism for multi-center dynamic contrast-enhanced breast MRI. We build a controlled AD benchmark of 17 realistic QA-relevant anomaly types from six public datasets (protocol violations, processing errors, incorrect anatomical regions) and propose a taxonomy of radiological image anomalies based on human visual perception, enabling fine-grained analysis of AD failure modes. The benchmark includes near-, medium-far-, far-OOD samples, as well as in-distribution and external normal data. Four methods are evaluated: a projection-based method extended with a domain-specific feature extractor and a novel positional encoding, a reconstruction-based approach extended to full 3D volumes with an augmented training objective, and two unmodified hybrid OOD detection methods. Medium-far- and far-OOD samples are detected reliably, whereas near-OOD samples and external normal data from unseen institutions expose method-specific differences. The 3D reconstruction-based approach best balances detection performance (AUROC: 0.936) and generalization to unseen institutions. The projection-based method with positional encoding achieves the highest overall detection performance (AUROC: 0.954). Both hybrid methods exhibit critical failure modes, confirming that methods validated for one modality or anatomy may not generalize without domain-specific adaptation. Implants and mastectomies remain an open challenge for all methods. Our results establish a foundation and practical guidance on scalable unsupervised QA in medical AI pipelines.

Abstract:Corrupted, inconsistent, or anomalous data silently threatens the safety and reliability of medical AI. Despite growing regulatory recognition of dataset quality assurance (QA) for high-risk medical AI, scalable automated detection remains underdeveloped. We employ unsupervised anomaly detection (AD) and out-of-distribution (OOD) detection as an automated dataset QA mechanism for multi-center dynamic contrast-enhanced breast MRI. We build a controlled AD benchmark of 17 realistic QA-relevant anomaly types from six public datasets (protocol violations, processing errors, incorrect anatomical regions) and propose a taxonomy of radiological image anomalies based on human visual perception, enabling fine-grained analysis of AD failure modes. The benchmark includes near-, medium-far-, far-OOD samples, as well as in-distribution and external normal data. Four methods are evaluated: a projection-based method extended with a domain-specific feature extractor and a novel positional encoding, a reconstruction-based approach extended to full 3D volumes with an augmented training objective, and two unmodified hybrid OOD detection methods. Medium-far- and far-OOD samples are detected reliably, whereas near-OOD samples and external normal data from unseen institutions expose method-specific differences. The 3D reconstruction-based approach best balances detection performance (AUROC: 0.936) and generalization to unseen institutions. The projection-based method with positional encoding achieves the highest overall detection performance (AUROC: 0.954). Both hybrid methods exhibit critical failure modes, confirming that methods validated for one modality or anatomy may not generalize without domain-specific adaptation. Implants and mastectomies remain an open challenge for all methods. Our results establish a foundation and practical guidance on scalable unsupervised QA in medical AI pipelines.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)

arXiv:2608.16725 [cs.CV]

(or arXiv:2608.16725v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2608.16725 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 347 words

Related coverage