aiqbench analysis
This study applies advanced machine learning techniques to contactless under-mattress sensing data, demonstrating that minute-level temporal modeling outperforms conventional nightly summaries in predicting agitation risk for dementia patients. While full-night sequence modeling achieved the highest discrimination metrics, the authors note that calibration remains limited and external validation is required before clinical deployment. The work highlights a promising intersection of biomedical engineering and AI research for improving patient care in specialized hospital settings.
Under-Mattress Temporal Sensing for Next-Day Agitation Risk Scoring in Dementia Wards
arXiv:2608.28152v1 Announce Type: new Abstract: Agitation fluctuates over short time horizons in people living with dementia, yet continuous physiological information for anticipating next-day risk is limited. We assessed whether contactless under-mattress signals from the preceding night inform next-day agitation risk and whether preserving minute-level temporal structure improves performance over conventional nightly summaries. We analyzed 423 patient-nights from 65 subjects in a specialized hospital dementia unit using two under-mattress sensing systems. A unified four-paradigm benchmark compared nightly handcrafted summaries, three-period handcrafted features, full-night sequence modeling, and sliding-window multiple-instance learning. Source-specific preprocessing and five-fold patient-grouped cross-validation were used, with performance estimated from pooled out-of-fold predictions. Evaluation included discrimination, calibration, fixed-threshold metrics, and a comparison of period-signal attribution patterns across two temporal models. Full-night sequence modeling achieved the highest discrimination (AUROC, 0.692; AUPRC, 0.849) and balanced accuracy (0.658). Both minute-level pipelines had higher AUROC than nightly summaries, but differences from three-period handcrafted features were uncertain. Cross-model attribution prioritized activity, heart rate, and respiratory rate during the core overnight period. Calibration remained limited. The preceding night's signals supported modest next-day risk discrimination, with minute-level temporal modeling outperforming nightly summaries. Prospective calibration and external validation are needed before use in individual care decisions. This patient-grouped benchmark identifies contactless overnight sensing as a promising biomedical engineering direction for agitation-risk research in hospitalized dementia cohorts.
Abstract:Agitation fluctuates over short time horizons in people living with dementia, yet continuous physiological information for anticipating next-day risk is limited. We assessed whether contactless under-mattress signals from the preceding night inform next-day agitation risk and whether preserving minute-level temporal structure improves performance over conventional nightly summaries. We analyzed 423 patient-nights from 65 subjects in a specialized hospital dementia unit using two under-mattress sensing systems. A unified four-paradigm benchmark compared nightly handcrafted summaries, three-period handcrafted features, full-night sequence modeling, and sliding-window multiple-instance learning. Source-specific preprocessing and five-fold patient-grouped cross-validation were used, with performance estimated from pooled out-of-fold predictions. Evaluation included discrimination, calibration, fixed-threshold metrics, and a comparison of period-signal attribution patterns across two temporal models. Full-night sequence modeling achieved the highest discrimination (AUROC, 0.692; AUPRC, 0.849) and balanced accuracy (0.658). Both minute-level pipelines had higher AUROC than nightly summaries, but differences from three-period handcrafted features were uncertain. Cross-model attribution prioritized activity, heart rate, and respiratory rate during the core overnight period. Calibration remained limited. The preceding night's signals supported modest next-day risk discrimination, with minute-level temporal modeling outperforming nightly summaries. Prospective calibration and external validation are needed before use in individual care decisions. This patient-grouped benchmark identifies contactless overnight sensing as a promising biomedical engineering direction for agitation-risk research in hospitalized dementia cohorts.
Artificial Intelligence (cs.AI); Machine Learning (cs.LG)
arXiv:2608.28152 [cs.AI]
(or arXiv:2608.28152v1 [cs.AI] for this version)
https://doi.org/10.48550/arXiv.2608.28152 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 310 words