aiqbench analysis
This study reveals that while INT8 quantization maintains safety for clinical LLMs, aggressive INT4 compression introduces significant, model-dependent risks to accuracy and emergency risk assessment. Crucially, the research demonstrates that clinical fine-tuning does not inherently protect against these degradation effects, and recovery strategies must be task-specific rather than universally applied. These findings are essential for deploying resource-constrained AI in healthcare, where balancing edge device efficiency with patient safety requires careful precision selection per model family.
The Effect of Quantization on Clinical Benchmarks: Accuracy and Safety Across Model Families
arXiv:2609.22216v1 Announce Type: cross Abstract: Quantization enables deployment of large language models on resource-constrained clinical edge devices, but its effect on clinical accuracy and safety remains understudied. We evaluate five 7-8B parameter models at FP16, GPTQ-INT8, and GPTQ-INT4 precision across five benchmarks: MedQA, MedMCQA, Med-HALT, a risk-stratified sample of HealthBench, and MedSafetyBench. The study jointly varies quantization bit width, model family, and clinical task type, with explicit risk stratification and safety measures. INT8 GPTQ is universally safe (max. degradation -1.9%-1.9%), while INT4 degradation is substantial and model-dependent: BioMistral-7B, clinically fine-tuned, loses 19.7% on MedMCQA, more than any general-purpose model, showing clinical fine-tuning does not confer compression robustness. MedMCQA degrades more than MedQA under INT4; Med-HALT is largely unaffected. On HealthBench's emergency-risk subgroup, Qwen2.5-7B degrades by 26.8% under INT4, suggesting high-risk scenarios are disproportionately vulnerable to compression. On MedSafetyBench, the model family dominates over precision (refusal rates range 10.2%-74.9% at FP16), though Qwen2.5-7B (-17.8%) and Meditron-7B (-28.3%) show substantial INT4 safety degradation; notably, Qwen2.5-7B is simultaneously the most accuracy-robust model, demonstrating that accuracy and safety robustness are independent properties. We additionally test two recovery methods, clinical calibration substitution and QLoRA fine-tuning, both producing the same trade-off: MedMCQA recovers while MedQA further degrades, indicating recovery strategies require task-specific validation rather than being assumed universally beneficial. These findings indicate INT8 is broadly safe for clinical deployment, while INT4 safety must be assessed per-model and per-task, and that safety alignment is determined primarily by instruction tuning rather than clinical domain adaptation.
Abstract:Quantization enables deployment of large language models on resource-constrained clinical edge devices, but its effect on clinical accuracy and safety remains understudied. We evaluate five 7-8B parameter models at FP16, GPTQ-INT8, and GPTQ-INT4 precision across five benchmarks: MedQA, MedMCQA, Med-HALT, a risk-stratified sample of HealthBench, and MedSafetyBench. The study jointly varies quantization bit width, model family, and clinical task type, with explicit risk stratification and safety measures. INT8 GPTQ is universally safe (max. degradation -1.9%-1.9%), while INT4 degradation is substantial and model-dependent: BioMistral-7B, clinically fine-tuned, loses 19.7% on MedMCQA, more than any general-purpose model, showing clinical fine-tuning does not confer compression robustness. MedMCQA degrades more than MedQA under INT4; Med-HALT is largely unaffected. On HealthBench's emergency-risk subgroup, Qwen2.5-7B degrades by 26.8% under INT4, suggesting high-risk scenarios are disproportionately vulnerable to compression. On MedSafetyBench, the model family dominates over precision (refusal rates range 10.2%-74.9% at FP16), though Qwen2.5-7B (-17.8%) and Meditron-7B (-28.3%) show substantial INT4 safety degradation; notably, Qwen2.5-7B is simultaneously the most accuracy-robust model, demonstrating that accuracy and safety robustness are independent properties. We additionally test two recovery methods, clinical calibration substitution and QLoRA fine-tuning, both producing the same trade-off: MedMCQA recovers while MedQA further degrades, indicating recovery strategies require task-specific validation rather than being assumed universally beneficial. These findings indicate INT8 is broadly safe for clinical deployment, while INT4 safety must be assessed per-model and per-task, and that safety alignment is determined primarily by instruction tuning rather than clinical domain adaptation.
Machine Learning (cs.LG); Computation and Language (cs.CL)
arXiv:2609.22216 [cs.LG]
(or arXiv:2609.22216v1 [cs.LG] for this version)
https://doi.org/10.48550/arXiv.2609.22216 Focus to learn more arXiv-issued DOI via DataCite
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 338 words


