Skip to content
aiqbench takeQuantum Comms

aiqbench analysis

This research demonstrates sub-shot-noise mid-infrared photothermal measurements using twin beams generated via seeded optical parametric amplification, effectively suppressing noise below the classical shot-noise limit. By achieving a 5 dB noise reduction and an SNR enhancement of over 2 dB in liquid water detection, the study advances quantum-enhanced sensing techniques for sensitive life science applications without increasing probe power.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Sub-shot-noise mid-infrared photothermal measurements using twin beams

arXiv2 min read

arXiv:2610.10294v1 Announce Type: cross Abstract: Mid-infrared photothermal (MIP) measurement probes refractive-index changes induced by mid-infrared (MIR) absorption using visible or near-infrared light and has recently emerged as a powerful modality for MIR spectro-imaging in the life sciences. Reducing measurement noise allows the probe power to be lowered without compromising the signal-to-noise ratio (SNR), thereby mitigating the risk of sample damage. However, even in the absence of classical noise, the SNR of conventional MIP measurements using a classical coherent probe is fundamentally limited by shot noise. Here, we demonstrate sub-shot-noise MIP measurement using twin beams generated through seeded optical parametric amplification. Balanced detection of the twin beams suppresses the noise by more than 5 dB below the shot-noise level established using a coherent beam. As a proof-of-principle demonstration, we measure the MIP signal from liquid water using balanced twin-beam detection and achieve an SNR enhancement of more than 2 dB over the balanced coherent-beam detection.

Abstract:Mid-infrared photothermal (MIP) measurement probes refractive-index changes induced by mid-infrared (MIR) absorption using visible or near-infrared light and has recently emerged as a powerful modality for MIR spectro-imaging in the life sciences. Reducing measurement noise allows the probe power to be lowered without compromising the signal-to-noise ratio (SNR), thereby mitigating the risk of sample damage. However, even in the absence of classical noise, the SNR of conventional MIP measurements using a classical coherent probe is fundamentally limited by shot noise. Here, we demonstrate sub-shot-noise MIP measurement using twin beams generated through seeded optical parametric amplification. Balanced detection of the twin beams suppresses the noise by more than 5 dB below the shot-noise level established using a coherent beam. As a proof-of-principle demonstration, we measure the MIP signal from liquid water using balanced twin-beam detection and achieve an SNR enhancement of more than 2 dB over the balanced coherent-beam detection.

Optics (physics.optics); Quantum Physics (quant-ph)

arXiv:2610.10294 [physics.optics]

(or arXiv:2610.10294v1 [physics.optics] for this version)

https://doi.org/10.48550/arXiv.2610.10294 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 245 words

Related coverage