Skip to content
aiqbench takeQuantum Comms

aiqbench analysis

This research addresses critical challenges in scaling quantum noise reduction for gravitational wave detectors by analyzing how thermal aberrations and mode mismatch degrade squeezed light states. The study distinguishes between low-pass and high-pass frequency behaviors in these degradations, providing essential insights for optimizing future detector designs with higher circulating power.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Squeezed state degradations due to mode mismatch and thermal aberrations in gravitational wave detectors

arXiv3 min read

arXiv:2604.23835v2 Announce Type: replace-cross Abstract: To date, frequency-dependent squeezed light has been used to reduce quantum noise in interferometric gravitational-wave detectors by 6.1 dB (a factor of two). Future upgrades and detectors aim to both reduce quantum noise by 10 dB (a factor of three) and to increase the circulating power in the interferometer arm cavities. Achieving these goals will be extremely challenging due, in part, to the degradations to the squeezed state caused by mode mismatch between the internal interferometer optical cavities and between the auxiliary external cavities. It is therefore imperative to gain a detailed understanding of all sources of mismatch and to obtain experience in mitigating their effects in the current detectors in order to improve astrophysical sensitivity now and in the future. Two types of internal mismatch are identified which are due to the thermal aberrations generated when the test mass optics absorb a small fraction of the circulating arm power. It is found that the dynamics responsible for the degradations caused by the mismatch between the quadratic part of the wavefront of two modes has a characteristic low-pass frequency dependence while the dynamics of the mismatch due to all higher order thermal aberrations has a high-pass behavior. As a consequence, the two types of mismatch are predominantly responsible for different squeezing degradations---some of which are significant for the current detectors and some of which will only be important for future detectors with longer arms. The behavior of these two types of internal mismatch are described, and the implications for detector design, operation, and characterization are discussed.

Abstract:To date, frequency-dependent squeezed light has been used to reduce quantum noise in interferometric gravitational-wave detectors by 6.1 dB (a factor of two). Future upgrades and detectors aim to both reduce quantum noise by 10 dB (a factor of three) and to increase the circulating power in the interferometer arm cavities. Achieving these goals will be extremely challenging due, in part, to the degradations to the squeezed state caused by mode mismatch between the internal interferometer optical cavities and between the auxiliary external cavities. It is therefore imperative to gain a detailed understanding of all sources of mismatch and to obtain experience in mitigating their effects in the current detectors in order to improve astrophysical sensitivity now and in the future. Two types of internal mismatch are identified which are due to the thermal aberrations generated when the test mass optics absorb a small fraction of the circulating arm power. It is found that the dynamics responsible for the degradations caused by the mismatch between the quadratic part of the wavefront of two modes has a characteristic low-pass frequency dependence while the dynamics of the mismatch due to all higher order thermal aberrations has a high-pass behavior. As a consequence, the two types of mismatch are predominantly responsible for different squeezing degradations---some of which are significant for the current detectors and some of which will only be important for future detectors with longer arms. The behavior of these two types of internal mismatch are described, and the implications for detector design, operation, and characterization are discussed.

Instrumentation and Detectors (physics.ins-det); Optics (physics.optics); Quantum Physics (quant-ph)

arXiv:2604.23835 [physics.ins-det]

(or arXiv:2604.23835v2 [physics.ins-det] for this version)

https://doi.org/10.48550/arXiv.2604.23835 Focus to learn more arXiv-issued DOI via DataCite

Phys. Rev. D 114, 042003 (2026)

https://doi.org/10.1103/97jj-h679 Focus to learn more DOI(s) linking to related resources

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 370 words

Related coverage