This research establishes fundamental scaling laws for cavity-enhanced optically pumped magnetometers (OPMs), demonstrating that sensitivity improvements scale with the square root of cavity finesse under critical coupling conditions. The study quantifies practical limits imposed by vector light-shift noise and provides optimization strategies for probe power and detuning in miniaturized, buffer-gas-filled vapor cells. These findings are pivotal for advancing portable quantum sensors used in biomagnetism and geophysics where size constraints necessitate cavity enhancement to overcome weak atom-light coupling.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Sensitivity Scaling and Limits of Cavity Enhancement in Miniaturized Optically Pumped Magnetometers

arXiv2 min read

arXiv:2608.16670v1 Announce Type: cross Abstract: The sensitivity of miniaturized optically pumped magnetometers (OPMs) is limited by weak atom-light coupling, which an optical cavity can enhance. In this work, we model the photon-shot-noise-limited sensitivity of cavity-enhanced OPMs in the regime of strongly collisionally broadened optical transitions, characteristic of buffer-gas-filled miniaturized vapor cells. The cavity enhancement is benchmarked against a single-pass free-induction-decay OPM employing Faraday-rotation readout, with the probe power and detuning jointly optimized using the Cram\'{e}r-Rao lower bound as a figure of merit. For a Fabry-P\'{e}rot cavity, we compare side-of-fringe, homodyne, Pound-Drever-Hall, and Faraday-rotation readout. All four yield an optimal sensitivity enhancement scaling as $\alpha\sqrt{2\mathcal{F}/\pi}$, where $\mathcal{F}$ is the cavity finesse and $0.5\leq \alpha \leq 1$ is a readout-dependent prefactor. The enhancement is maximized at critical coupling, and we quantify its degradation away from this point. We further show that, despite spin-dependent absorption associated with the ensemble's vector polarizability, near-critical coupling can be maintained throughout spin precession at arbitrary finesse by exceeding a derived probe-power threshold and increasing the atomic detuning with finesse. We also establish a limit to the maximum cavity enhancement set by vector light-shift noise.

Abstract:The sensitivity of miniaturized optically pumped magnetometers (OPMs) is limited by weak atom-light coupling, which an optical cavity can enhance. In this work, we model the photon-shot-noise-limited sensitivity of cavity-enhanced OPMs in the regime of strongly collisionally broadened optical transitions, characteristic of buffer-gas-filled miniaturized vapor cells. The cavity enhancement is benchmarked against a single-pass free-induction-decay OPM employing Faraday-rotation readout, with the probe power and detuning jointly optimized using the Cramér-Rao lower bound as a figure of merit. For a Fabry-Pérot cavity, we compare side-of-fringe, homodyne, Pound-Drever-Hall, and Faraday-rotation readout. All four yield an optimal sensitivity enhancement scaling as $\alpha\sqrt{2\mathcal{F}/\pi}$, where $\mathcal{F}$ is the cavity finesse and $0.5\leq \alpha \leq 1$ is a readout-dependent prefactor. The enhancement is maximized at critical coupling, and we quantify its degradation away from this point. We further show that, despite spin-dependent absorption associated with the ensemble's vector polarizability, near-critical coupling can be maintained throughout spin precession at arbitrary finesse by exceeding a derived probe-power threshold and increasing the atomic detuning with finesse. We also establish a limit to the maximum cavity enhancement set by vector light-shift noise.

Atomic Physics (physics.atom-ph); Quantum Physics (quant-ph)

arXiv:2608.16670 [physics.atom-ph]

(or arXiv:2608.16670v1 [physics.atom-ph] for this version)

https://doi.org/10.48550/arXiv.2608.16670 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 279 words

Related coverage