This paper introduces SCMA, a novel Flow Matching framework designed to mitigate metal artifacts in X-ray CT scans by integrating sample-specific structural conditions and spatially weighted loss functions. By leveraging measured projections during inference, the method effectively suppresses streaks while preserving anatomical integrity without relying on hallucinated structures common in unconditional generative models. The approach advances medical imaging capabilities through a rigorous application of machine learning techniques to solve specific physical degradation problems inherent in CT reconstruction.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

SCMA: Structure-Conditioned and Metal-Aware Flow Matching for CT Metal Artifact Reduction

arXiv3 min read

arXiv:2607.28759v1 Announce Type: cross Abstract: In X-ray CT, metallic objects cause beam hardening, photon starvation, and scattering, leading to projection inconsistency, streaks, dark bands, and structural distortions that compromise clinical diagnosis and quantitative analysis. Existing metal artifact reduction (MAR) methods remain limited: optimization-based methods may leave residual artifacts or blur structures, regression networks may generalize poorly across scenarios, and generative models without sample-specific structural guidance and physical constraints may produce anatomically inconsistent structures. Flow Matching learns a continuous-time velocity field that deterministically transports a source distribution to a target distribution, providing a flexible MAR prior. However, standard unconditional Flow Matching does not exploit sample-specific structure, spatially nonuniform metal-induced degradation, or measured projections. To address these limitations, we propose SCMA, a structure-conditioned and metal-aware Flow Matching framework. First, a linear-interpolation-corrected image is fed into the velocity network with the intermediate state as a sample-specific structural condition, guiding inference toward artifact-free CT images while preserving anatomy. Second, time-varying spatial weights from the metal mask and its distance transform are incorporated into the Flow Matching loss to emphasize severe degradation within and around metal regions. Finally, conditional Flow Matching updates alternate with projection-consistency correction during inference, allowing reliable measurements outside metal traces to constrain predictions. Experiments on simulated and real CT data demonstrate that SCMA more effectively suppresses metal artifacts, preserves local anatomical structures, and reduces hallucination-like structures inconsistent with projection measurements than representative MAR methods.

Abstract:In X-ray CT, metallic objects cause beam hardening, photon starvation, and scattering, leading to projection inconsistency, streaks, dark bands, and structural distortions that compromise clinical diagnosis and quantitative analysis. Existing metal artifact reduction (MAR) methods remain limited: optimization-based methods may leave residual artifacts or blur structures, regression networks may generalize poorly across scenarios, and generative models without sample-specific structural guidance and physical constraints may produce anatomically inconsistent structures. Flow Matching learns a continuous-time velocity field that deterministically transports a source distribution to a target distribution, providing a flexible MAR prior. However, standard unconditional Flow Matching does not exploit sample-specific structure, spatially nonuniform metal-induced degradation, or measured projections. To address these limitations, we propose SCMA, a structure-conditioned and metal-aware Flow Matching framework. First, a linear-interpolation-corrected image is fed into the velocity network with the intermediate state as a sample-specific structural condition, guiding inference toward artifact-free CT images while preserving anatomy. Second, time-varying spatial weights from the metal mask and its distance transform are incorporated into the Flow Matching loss to emphasize severe degradation within and around metal regions. Finally, conditional Flow Matching updates alternate with projection-consistency correction during inference, allowing reliable measurements outside metal traces to constrain predictions. Experiments on simulated and real CT data demonstrate that SCMA more effectively suppresses metal artifacts, preserves local anatomical structures, and reduces hallucination-like structures inconsistent with projection measurements than representative MAR methods.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)

arXiv:2607.28759 [cs.CV]

(or arXiv:2607.28759v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2607.28759 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 328 words

Related coverage