aiqbench analysis
This research addresses a critical bottleneck in medical AI by leveraging routine radiologist annotations to automatically generate large-scale 3D visual grounding datasets for abdominal CT scans. By converting existing 2D markings into volumetric phrase-mask triplets, the authors eliminate the need for expensive manual labeling while establishing new benchmarks that demonstrate significant performance gains over prior models. The work effectively bridges computer vision techniques with clinical workflow realities, offering a scalable path toward more precise AI-assisted radiology tools.
Scaling 3D Visual Grounding in Abdominal CT
arXiv:2610.04095v1 Announce Type: cross Abstract: Visual grounding models can enhance radiology workflows by linking report findings to image regions. This is particularly valuable for 3D CT, where findings often occupy a tiny fraction of the volume. Training 3D grounding models requires large sets of paired phrases and regions, and building such datasets is expensive, requiring radiologists to annotate images by hand. We posit that this supervision is already created implicitly during routine reporting, as radiologists frequently place 2D annotations (e.g., distance measurement, arrows) on key images to make measurements and to support report interpretation. We introduce an automated pipeline that converts these routine clinical annotations into large-scale phrase-region supervision for 3D visual grounding. The pipeline links each annotation to the corresponding finding in the report through metadata matching, then uses a promptable 3D segmentation model to convert the 2D annotation into a volumetric mask. This produces phrase-mask-volume datasets without requiring additional radiologist annotation. Applied to a single institution's clinical picture archiving and communication system (PACS), our approach generated 105K phrase-mask-volume triplets from 59K abdominal CT exams. We also introduce two abdominal CT grounding benchmarks, LocusBench-Onc and LocusBench-ED, which comprise 240 oncology and 260 emergency-department radiologist-reviewed phrase-mask-volume triplets, respectively, with the latter spanning 13 distinct categories such as appendicitis, hematoma, and hernia. We further introduce LocusCT, a 3D visual grounding model trained on this dataset, which achieves hit rates of 0.725 on LocusBench-Onc and 0.773 on LocusBench-ED, substantially outperforming comparator models. These results show that routine PACS annotations are a scalable, previously unused source of supervision for 3D visual grounding.
Abstract:Visual grounding models can enhance radiology workflows by linking report findings to image regions. This is particularly valuable for 3D CT, where findings often occupy a tiny fraction of the volume. Training 3D grounding models requires large sets of paired phrases and regions, and building such datasets is expensive, requiring radiologists to annotate images by hand. We posit that this supervision is already created implicitly during routine reporting, as radiologists frequently place 2D annotations (e.g., distance measurement, arrows) on key images to make measurements and to support report interpretation. We introduce an automated pipeline that converts these routine clinical annotations into large-scale phrase-region supervision for 3D visual grounding. The pipeline links each annotation to the corresponding finding in the report through metadata matching, then uses a promptable 3D segmentation model to convert the 2D annotation into a volumetric mask. This produces phrase-mask-volume datasets without requiring additional radiologist annotation. Applied to a single institution's clinical picture archiving and communication system (PACS), our approach generated 105K phrase-mask-volume triplets from 59K abdominal CT exams. We also introduce two abdominal CT grounding benchmarks, LocusBench-Onc and LocusBench-ED, which comprise 240 oncology and 260 emergency-department radiologist-reviewed phrase-mask-volume triplets, respectively, with the latter spanning 13 distinct categories such as appendicitis, hematoma, and hernia. We further introduce LocusCT, a 3D visual grounding model trained on this dataset, which achieves hit rates of 0.725 on LocusBench-Onc and 0.773 on LocusBench-ED, substantially outperforming comparator models. These results show that routine PACS annotations are a scalable, previously unused source of supervision for 3D visual grounding.
Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG)
arXiv:2610.04095 [cs.CV]
(or arXiv:2610.04095v1 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2610.04095 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 354 words
Related coverage

Presentation: Engineering AI for Creativity and Curiosity on Mobile
InfoQ · Jul 21, 2026

Article: The AI Productivity Paradox in Test Automation: Moving beyond Structural Validation to Perception and Intent
InfoQ · Jun 1, 2026

Inference meta-monitoring for Amazon SageMaker AI endpoints with Amazon Quick
AWS · Jul 30, 2026
PathScale-R1: Cross-scale Reasoning for Pathological Image Analysis
arXiv · Jul 28, 2026