aiqbench analysis
This research advances NV center magnetometry by implementing concatenated continuous dynamical decoupling to maintain sub-picotesla sensitivity in GHz-range AC fields despite spatial inhomogeneities. The method extends the measurement range for weak signals compared to conventional Rabi oscillation techniques, offering a more robust approach for ensemble-based sensing.
Robust gigahertz-range ac magnetometry with an ensemble of NV centers in diamond using concatenated continuous dynamical decoupling
arXiv:2510.20401v2 Announce Type: replace Abstract: Sub-picotesla level magnetometry has been demonstrated using negatively-charged nitrogen-vacancy (NV) centers in diamond by increasing the number of spins simultaneously used for sensing in an NV ensemble. However, such scale-up often introduces spatial inhomogeneities in detuning and control field amplitudes, which degrade sensitivity. Although several techniques have been utilized to overcome these challenges, including pulsed dynamical decoupling or shaped pulses, these are not generally compatible with the current state-of-the-art techniques for GHz-range AC magnetometry with NV ensembles, which are typically based on Rabi oscillations. In this work we experimentally demonstrate GHz-range AC magnetometry using a large ensemble of NV centers under spatially inhomogeneous drive fields by employing concatenated continuous dynamical decoupling, which is designed for robustness against such imperfections. We compare its performance with the conventional direct Rabi method and show that the robust dressed states in our method extend significantly the measuring range to weaker signals in GHz-range AC magnetometry.
Abstract:Sub-picotesla level magnetometry has been demonstrated using negatively-charged nitrogen-vacancy (NV) centers in diamond by increasing the number of spins simultaneously used for sensing in an NV ensemble. However, such scale-up often introduces spatial inhomogeneities in detuning and control field amplitudes, which degrade sensitivity. Although several techniques have been utilized to overcome these challenges, including pulsed dynamical decoupling or shaped pulses, these are not generally compatible with the current state-of-the-art techniques for GHz-range AC magnetometry with NV ensembles, which are typically based on Rabi oscillations. In this work we experimentally demonstrate GHz-range AC magnetometry using a large ensemble of NV centers under spatially inhomogeneous drive fields by employing concatenated continuous dynamical decoupling, which is designed for robustness against such imperfections. We compare its performance with the conventional direct Rabi method and show that the robust dressed states in our method extend significantly the measuring range to weaker signals in GHz-range AC magnetometry.
Accepted version. Published in Physical Review Applied 26, 024018 (2026). 23 pages, 25 figures
arXiv:2510.20401 [quant-ph]
(or arXiv:2510.20401v2 [quant-ph] for this version)
https://doi.org/10.48550/arXiv.2510.20401 Focus to learn more arXiv-issued DOI via DataCite
https://doi.org/10.1103/8zf5-1zyj Focus to learn more DOI(s) linking to related resources
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 264 words
Related coverage

Non-Gaussian Noise Magnetometry Using Local Spin Qubits
Quantum Journal · Aug 27, 2026

New chip makes quantum sensors simpler to build
Quantum Zeitgeist · Oct 3, 2026

News
Quantum Computing Report · Jun 7, 2026

Phys: MIT Engineers Boost Coherence Times by 7× in Spin Ensembles
Quantum Zeitgeist · Jun 17, 2026