Skip to content
aiqbench takeAI Research

aiqbench analysis

This paper proposes a protocol for checking whether a medical-imaging model's benchmark score depends on data reuse between training and validation sets. Its central point is that a large score drop after removing overlapping sources reflects sensitivity to those sources, not a measure of leakage-driven inflation, and the reversal on other sources shows why. For evaluators, the useful takeaway is the discipline of stating the population, class support, and uncertainty unit behind each conclusion.
Source coveringarXiv

ReuScope: Auditing Data Reuse and Evaluation Sensitivity in Capsule Vision 2024

arXiv3 min read

arXiv:2610.41835v1 Announce Type: new Abstract: We develop ReuScope, a protocol for auditing data reuse and evaluation sensitivity, using Capsule Vision 2024 as a case study. It combines measurements of data relationships with two comparisons: changing the evaluation population while holding predictions fixed, and changing training data while holding evaluation fixed. Byte-identical files cross the public training-validation boundary, and all 41 Kvasir-Capsule recordings that contribute frames occur in both partitions. Shared source recordings establish cross-split overlap; missing cross-recording patient identifiers prevent counting unique shared patients. Across ten paired seeds, removing all training rows attributed to Kvasir-Capsule, plus five rows from other sources flagged as near-matches to it, lowers public-validation balanced accuracy from 82.5% to 61.2%. Evaluating the same fitted models on the validation rows of the other sources reverses the comparison: removal improves balanced accuracy by 1.38 percentage points. The public-validation drop measures sensitivity to source removal, not an amount of leakage-induced inflation. Matched controls show that sample size and class counts alone do not explain the observed score differences. An exploratory experiment removes the training neighbors of validation frames that have close training matches, or equally many distant training rows, and yields a difference-in-differences estimate, relative to matched unflagged frames, of -0.355 percentage points in true-class probability; the paired-t interval for accuracy spans zero. The resulting procedure distinguishes observed reuse from conditional performance sensitivity and specifies the population, class support and uncertainty unit for each conclusion.

Abstract:We develop ReuScope, a protocol for auditing data reuse and evaluation sensitivity, using Capsule Vision 2024 as a case study. It combines measurements of data relationships with two comparisons: changing the evaluation population while holding predictions fixed, and changing training data while holding evaluation fixed. Byte-identical files cross the public training-validation boundary, and all 41 Kvasir-Capsule recordings that contribute frames occur in both partitions. Shared source recordings establish cross-split overlap; missing cross-recording patient identifiers prevent counting unique shared patients. Across ten paired seeds, removing all training rows attributed to Kvasir-Capsule, plus five rows from other sources flagged as near-matches to it, lowers public-validation balanced accuracy from 82.5% to 61.2%. Evaluating the same fitted models on the validation rows of the other sources reverses the comparison: removal improves balanced accuracy by 1.38 percentage points. The public-validation drop measures sensitivity to source removal, not an amount of leakage-induced inflation. Matched controls show that sample size and class counts alone do not explain the observed score differences. An exploratory experiment removes the training neighbors of validation frames that have close training matches, or equally many distant training rows, and yields a difference-in-differences estimate, relative to matched unflagged frames, of -0.355 percentage points in true-class probability; the paired-t interval for accuracy spans zero. The resulting procedure distinguishes observed reuse from conditional performance sensitivity and specifies the population, class support and uncertainty unit for each conclusion.

Accepted at NeurIPS 2026, Track on Evaluations and Datasets. 39 pages, 3 figures. Code and data: this https URL

Artificial Intelligence (cs.AI); Computer Vision and Pattern Recognition (cs.CV)

arXiv:2610.41835 [cs.AI]

(or arXiv:2610.41835v1 [cs.AI] for this version)

https://doi.org/10.48550/arXiv.2610.41835 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 350 words