This study demonstrates that a 2.5D U-Net architecture can effectively detect gaseous microemboli in cardiac surgery video feeds while maintaining real-time inference speeds, offering a practical solution to the limitations of traditional spot detection and standard 2D models. The research validates deep learning's utility in medical imaging by achieving high precision without sacrificing computational efficiency required for intraoperative decision-making.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Protect the Brain When Treating the Heart: Feasibility of 2.5D U-Net for Real-Time Gaseous Microemboli Detection

arXiv3 min read

arXiv:2604.22258v2 Announce Type: replace Abstract: Gaseous microemboli (GME) represent a common complication of cardiac structural interventions across both surgical and transcatheter approaches. Intraoperative transesophageal echocardiography (TEE) represents a convenient methodology to monitor and visualize the presence of circulating GME. However, their detection and quantification are far from trivial due to operator-dependent view, high velocity, and objects with similar structure in the background. Here, we propose a feasibility study based on a 2.5D U-Net architecture to detect GME in space-time connected data. We applied and tested such an architecture on a pilot dataset of eight TEE recordings ($60$ fps, $600\times 800$ pixels) from eight different patients undergoing cardiac surgery, resulting in improved detection of moving GMEs against the background with respect to classical spot detection algorithms and 2D U-Net, yet retaining real-time execution speed with respect to more complex deep-learning architectures. Under leave-one-patient-out cross-validation, the selected model achieved strong detection performance under a three-pixel radius-tolerant grace-zone evaluation, with a precision of 92.55\% and recall of 80.54\%, corresponding to radius-tolerant Intersection over Union (IoU) and Dice coefficients of 73.95\% and 84.13\%, respectively. Complementarily, strict pixel-based segmentation metrics were also computed, yielding an IoU of 41.74\% and a Dice coefficient of 57.98\%. The selected model achieved an average inference time of $0.12 s$ per batch on the tested hardware. To assess specificity on unseen data, we additionally evaluated the model on an external GME-negative TEE dataset, where it produced predominantly empty or near-empty masks, indicating a low rate of spurious detections. These results support the technical feasibility of real-time GME segmentation.

Title:Protect the Brain When Treating the Heart: Feasibility of 2.5D U-Net for Real-Time Gaseous Microemboli Detection

Abstract:Gaseous microemboli (GME) represent a common complication of cardiac structural interventions across both surgical and transcatheter approaches. Intraoperative transesophageal echocardiography (TEE) represents a convenient methodology to monitor and visualize the presence of circulating GME. However, their detection and quantification are far from trivial due to operator-dependent view, high velocity, and objects with similar structure in the background. Here, we propose a feasibility study based on a 2.5D U-Net architecture to detect GME in space-time connected data. We applied and tested such an architecture on a pilot dataset of eight TEE recordings ($60$ fps, $600\times 800$ pixels) from eight different patients undergoing cardiac surgery, resulting in improved detection of moving GMEs against the background with respect to classical spot detection algorithms and 2D U-Net, yet retaining real-time execution speed with respect to more complex deep-learning architectures. Under leave-one-patient-out cross-validation, the selected model achieved strong detection performance under a three-pixel radius-tolerant grace-zone evaluation, with a precision of 92.55\% and recall of 80.54\%, corresponding to radius-tolerant Intersection over Union (IoU) and Dice coefficients of 73.95\% and 84.13\%, respectively. Complementarily, strict pixel-based segmentation metrics were also computed, yielding an IoU of 41.74\% and a Dice coefficient of 57.98\%. The selected model achieved an average inference time of $0.12 s$ per batch on the tested hardware. To assess specificity on unseen data, we additionally evaluated the model on an external GME-negative TEE dataset, where it produced predominantly empty or near-empty masks, indicating a low rate of spurious detections. These results support the technical feasibility of real-time GME segmentation.

Under review. Corresponding authors: Andrea Angino and Diego Ulisse Pizzagalli

Machine Learning (cs.LG); Artificial Intelligence (cs.AI)

arXiv:2604.22258 [cs.LG]

(or arXiv:2604.22258v2 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2604.22258 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 374 words

Related coverage