Skip to content
aiqbench takeMachine Learning

aiqbench analysis

TechPulse take: PP-Net addresses a critical bottleneck in Internet of Medical Things applications by combining physical priors with neural networks to remove scattered light from biomedical images where ground truth is unavailable. The architecture successfully balances high restoration quality with the computational constraints of edge devices, achieving real-time inference through quantization and optimization for embedded hardware. This approach represents a significant step forward for practical AI deployment in resource-constrained medical imaging scenarios.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

PP-Net: A Hybrid Physical-Prior Neural Network for Scattered Light Removal in Biomedical Images on Embedded Devices

arXiv3 min read

arXiv:2609.26474v1 Announce Type: cross Abstract: Scattered light is common in biomedical images, yet its removal remains challenging. The difficulty arises from three aspects: first, aligned scattered-light-free biomedical ground truth is often unavailable; second, scattering is coupled with weak illumination and sensor-induced noise; and third, many learning-based restoration models are computationally expensive for embedded devices in Internet of Medical Things (IoMT) scenarios. To address these issues, this paper proposes PP-Net, a hybrid physical-prior neural network for biomedical scattered light removal. The proposed method consists of three components: DFN-Net suppresses sensor-induced noise, ASAP estimates the scattering map and recovers a physics-based prior map, and GF-Net refines the prior map by fusing it with the denoised observation. To reduce the dependence on paired biomedical ground truth, a progressive synthetic training and cross-domain transfer strategy is developed. Experiments show that the physical-prior branch improves the peak signal-to-noise ratio (PSNR) by up to 1.26 dB on paired synthetic benchmarks. Under joint noise-and-scattering degradation, PP-Net improves PSNR by more than 10.8 dB and the structural similarity index measure (SSIM) by more than 0.62 compared with representative baseline methods. On real W2S biomedical images, the proposed method reduces the average Natural Image Quality Evaluator (NIQE) score by 43.3\%. Edge deployment with RKNN conversion and INT8 quantization achieves an average inference latency of approximately 200 ms per $512\times512$ image over 360 test images. These results demonstrate that PP-Net provides an effective and deployable solution for microscopic imaging, endoscopic inspection, and edge-assisted biomedical analysis in IoMT scenarios.

Abstract:Scattered light is common in biomedical images, yet its removal remains challenging. The difficulty arises from three aspects: first, aligned scattered-light-free biomedical ground truth is often unavailable; second, scattering is coupled with weak illumination and sensor-induced noise; and third, many learning-based restoration models are computationally expensive for embedded devices in Internet of Medical Things (IoMT) scenarios. To address these issues, this paper proposes PP-Net, a hybrid physical-prior neural network for biomedical scattered light removal. The proposed method consists of three components: DFN-Net suppresses sensor-induced noise, ASAP estimates the scattering map and recovers a physics-based prior map, and GF-Net refines the prior map by fusing it with the denoised observation. To reduce the dependence on paired biomedical ground truth, a progressive synthetic training and cross-domain transfer strategy is developed. Experiments show that the physical-prior branch improves the peak signal-to-noise ratio (PSNR) by up to 1.26 dB on paired synthetic benchmarks. Under joint noise-and-scattering degradation, PP-Net improves PSNR by more than 10.8 dB and the structural similarity index measure (SSIM) by more than 0.62 compared with representative baseline methods. On real W2S biomedical images, the proposed method reduces the average Natural Image Quality Evaluator (NIQE) score by 43.3\%. Edge deployment with RKNN conversion and INT8 quantization achieves an average inference latency of approximately 200 ms per $512\times512$ image over 360 test images. These results demonstrate that PP-Net provides an effective and deployable solution for microscopic imaging, endoscopic inspection, and edge-assisted biomedical analysis in IoMT scenarios.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI); Machine Learning (cs.LG); Image and Video Processing (eess.IV); Signal Processing (eess.SP)

arXiv:2609.26474 [cs.CV]

(or arXiv:2609.26474v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2609.26474 arXiv-issued DOI via DataCite (pending registration)

Full text under the publisher's open licence · 278 words

Related coverage