Skip to content
aiqbench takeAI Research

aiqbench analysis

This research introduces PLS-Calib, a novel framework using Partial Least Squares regression to solve rotation calibration for ground-constrained robots equipped with event cameras and odometry systems. By leveraging latent kinematic correlations in asynchronous sensor streams, the method provides a stable closed-form solution that overcomes numerical instability issues found in traditional Canonical Correlation Analysis approaches. The work represents a significant advancement in neuromorphic vision applications where full 6-DoF motion is physically unattainable for mobile platforms.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

PLS-Calib: A Partial Least Squares Framework for Event Camera and Odometry Calibration under Ground Motion Constraints

arXiv3 min read

arXiv:2608.03296v1 Announce Type: new Abstract: Accurate extrinsic rotation calibration between sensors is fundamental to the performance of robotic perception systems. However, most existing calibration techniques rely on full 6-DoF motion to excite all degrees of freedom, which is often infeasible for ground-constrained robots with limited motion capabilities. Recent approaches designed for such restricted settings, such as Canonical Correlation Analysis (CCA)-based methods, suffer from ill-conditioned covariance matrices that lead to numerical instability and suboptimal calibration accuracy. To overcome these limitations, we present a novel rotation calibration framework named PLS-Calib that, for the first time, leverages Partial Least Squares (PLS) regression to model the latent kinematic correlations between asynchronous, heterogeneous sensor streams. Specifically, we apply our method to the calibration of an event camera and an odometry onboard a ground robot. To improve event-based pattern detection, we introduce a polarity-aware event representation, which enhances spatiotemporal contrast in circular calibration targets. Our PLS-based formulation yields a closed-form, stable solution that avoids matrix singularities inherent in CCA-based approaches. Extensive experiments on both synthetic and real-world datasets validate the effectiveness of our approach, demonstrating significant improvements in calibration robustness and accuracy over state-of-the-art methods. This work offers a practical and theoretically grounded solution for rotation calibration in constrained robotic systems and opens up new directions for applying statistical learning techniques in neuromorphic vision.

Abstract:Accurate extrinsic rotation calibration between sensors is fundamental to the performance of robotic perception systems. However, most existing calibration techniques rely on full 6-DoF motion to excite all degrees of freedom, which is often infeasible for ground-constrained robots with limited motion capabilities. Recent approaches designed for such restricted settings, such as Canonical Correlation Analysis (CCA)-based methods, suffer from ill-conditioned covariance matrices that lead to numerical instability and suboptimal calibration accuracy. To overcome these limitations, we present a novel rotation calibration framework named PLS-Calib that, for the first time, leverages Partial Least Squares (PLS) regression to model the latent kinematic correlations between asynchronous, heterogeneous sensor streams. Specifically, we apply our method to the calibration of an event camera and an odometry onboard a ground robot. To improve event-based pattern detection, we introduce a polarity-aware event representation, which enhances spatiotemporal contrast in circular calibration targets. Our PLS-based formulation yields a closed-form, stable solution that avoids matrix singularities inherent in CCA-based approaches. Extensive experiments on both synthetic and real-world datasets validate the effectiveness of our approach, demonstrating significant improvements in calibration robustness and accuracy over state-of-the-art methods. This work offers a practical and theoretically grounded solution for rotation calibration in constrained robotic systems and opens up new directions for applying statistical learning techniques in neuromorphic vision.

8 pages, 10 figures, 4 tables. Accepted at the 2026 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2026)

Robotics (cs.RO); Computer Vision and Pattern Recognition (cs.CV)

arXiv:2608.03296 [cs.RO]

(or arXiv:2608.03296v1 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2608.03296 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 332 words

Related coverage