Trajectory-based features transferred across hospitals and datasets more reliably than observation-pattern features, which helped only in locally fitted models and were sensitive to when and how often measurements were taken. For ML readers, the main point is that external validation alone can miss failures caused by changes in measurement conditions, so evaluation should also stress-test inputs such as timing and availability.
Physiological Trajectories and Observation Patterns in ICU Mortality Prediction: Transportability Under Changing Measurement Conditions
arXiv:2610.42126v1 Announce Type: new Abstract: Objective: To distinguish the transferable predictive value of physiological trajectories from that of observation patterns in ICU mortality prediction, and to assess whether measurement timing affects performance independently of observation quantity. Materials and Methods: In-hospital mortality was predicted at 48 hours using MIMIC-III, MIMIC-IV, and eICU. Nested representations progressively integrated latest-value snapshots (R1), longitudinal physiological summaries (R2), and measurement frequency and timing features (R3). Models fitted on 7,762 MetaVision patients were evaluated on 21,682 MIMIC-IV patients and 43,878 eICU patients across 204 hospitals. The effect of measurement timing was assessed while holding the number of retained observations constant. Results: Physiological trajectories improved external prediction in eICU (R2-R1 log-loss difference -0.00922, 95% CI -0.01148 to -0.00704). Observation-pattern features improved locally developed eICU models (R3-R2 -0.00257, 95% CI -0.00370 to -0.00146), but not clearly after transfer from MetaVision (-0.00012, 95% CI -0.00206 to +0.00208). R3 was favoured in 10 of 30 source bootstrap refits. At matched observation counts, retaining measurements spread throughout the window reduced log loss relative to random retention by 0.03280 for R3 versus 0.00703 for R2. Removing the final 12 hours increased log loss relative to count-matched random removal by 0.01947 for R3 versus 0.00822 for R2. Under reduced availability, the local R3 increment changed from beneficial to harmful. Discussion: Physiological trajectories transferred more consistently, while observation-pattern features were particularly sensitive to the timing and availability of measurements. Conclusion: Clinical prediction models should be evaluated not only in new patient populations but also under the measurement conditions that supply their inputs.
Abstract:Objective: To distinguish the transferable predictive value of physiological trajectories from that of observation patterns in ICU mortality prediction, and to assess whether measurement timing affects performance independently of observation quantity. Materials and Methods: In-hospital mortality was predicted at 48 hours using MIMIC-III, MIMIC-IV, and eICU. Nested representations progressively integrated latest-value snapshots (R1), longitudinal physiological summaries (R2), and measurement frequency and timing features (R3). Models fitted on 7,762 MetaVision patients were evaluated on 21,682 MIMIC-IV patients and 43,878 eICU patients across 204 hospitals. The effect of measurement timing was assessed while holding the number of retained observations constant. Results: Physiological trajectories improved external prediction in eICU (R2-R1 log-loss difference -0.00922, 95% CI -0.01148 to -0.00704). Observation-pattern features improved locally developed eICU models (R3-R2 -0.00257, 95% CI -0.00370 to -0.00146), but not clearly after transfer from MetaVision (-0.00012, 95% CI -0.00206 to +0.00208). R3 was favoured in 10 of 30 source bootstrap refits. At matched observation counts, retaining measurements spread throughout the window reduced log loss relative to random retention by 0.03280 for R3 versus 0.00703 for R2. Removing the final 12 hours increased log loss relative to count-matched random removal by 0.01947 for R3 versus 0.00822 for R2. Under reduced availability, the local R3 increment changed from beneficial to harmful. Discussion: Physiological trajectories transferred more consistently, while observation-pattern features were particularly sensitive to the timing and availability of measurements. Conclusion: Clinical prediction models should be evaluated not only in new patient populations but also under the measurement conditions that supply their inputs.
10 pages, 3 figures, 3 tables. Supplementary material available as an ancillary file
Machine Learning (cs.LG); Quantitative Methods (q-bio.QM)
arXiv:2610.42126 [cs.LG]
(or arXiv:2610.42126v1 [cs.LG] for this version)
https://doi.org/10.48550/arXiv.2610.42126 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
Supplementary_Material.pdf
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 363 words
Related coverage
Molecular Dynamics-Derived Coloured Noise Mediates Anderson Localisation and Environment-Assisted Transport of Tryptophan Excitons in Tubulin
arXiv · Jul 21, 2026

Molecular Dynamics Reveal Nanosecond Tubulin Conformational Shifts
Quantum Zeitgeist · Jul 14, 2026
Conditional Quantum Flow Matching for Data-Scarce Physiological Signal Augmentation
arXiv · Sep 15, 2026
Capturing Cardiac Cyclicity through Phase-Equivariant Self-Supervised Learning
arXiv · Aug 24, 2026