Skip to content
aiqbench takeQuantum Computing

aiqbench analysis

This research demonstrates a breakthrough in quantum readout fidelity by utilizing a cascaded Josephson and traveling-wave parametric amplifier to achieve noise temperatures well below the standard quantum limit. By leveraging phase-sensitive operation, the system enables direct, high-fidelity probing of superconducting qubits without requiring background noise subtraction, which is critical for scaling up quantum processors.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Phase-sensitive cascade quantum amplifier with nearly noiseless operation

arXiv2 min read

arXiv:2608.25645v1 Announce Type: new Abstract: Phase-sensitive parametric devices enable quadrature-selective amplification with the potential for sub-quantum-limited noise performance. In this work, we investigate the operation of a SQUID-based Josephson Parametric Amplifier (JPA), comparing its performance in the phase-preserving and phase-sensitive regimes. The device, fabricated using VTT SWAPS technology, is driven in a three-wave mixing configuration and characterized in a reflection-based measurement setup at millikelvin temperatures. To directly probe the noise performance at low JPA gains, we employ a cascaded amplification scheme in which a Traveling-Wave Parametric Amplifier (TWPA) provides low-noise pre-amplification of the JPA output. In a phase-preserving operation, the JPA exhibits near-quantum-limited performance with a system noise temperature of $351\pm53$ mK at 6 GHz. In contrast, phase-sensitive operation yields a minimum system noise temperature of $94\pm12$ mK, well below the standard quantum limit of 288 mK. Our results demonstrate that a JPA-TWPA amplifier cascade opens the door to direct, high-fidelity probing of quantum devices without the need for background noise subtraction.

Abstract:Phase-sensitive parametric devices enable quadrature-selective amplification with the potential for sub-quantum-limited noise performance. In this work, we investigate the operation of a SQUID-based Josephson Parametric Amplifier (JPA), comparing its performance in the phase-preserving and phase-sensitive regimes. The device, fabricated using VTT SWAPS technology, is driven in a three-wave mixing configuration and characterized in a reflection-based measurement setup at millikelvin temperatures. To directly probe the noise performance at low JPA gains, we employ a cascaded amplification scheme in which a Traveling-Wave Parametric Amplifier (TWPA) provides low-noise pre-amplification of the JPA output. In a phase-preserving operation, the JPA exhibits near-quantum-limited performance with a system noise temperature of $351\pm53$ mK at 6 GHz. In contrast, phase-sensitive operation yields a minimum system noise temperature of $94\pm12$ mK, well below the standard quantum limit of 288 mK. Our results demonstrate that a JPA-TWPA amplifier cascade opens the door to direct, high-fidelity probing of quantum devices without the need for background noise subtraction.

Quantum Physics (quant-ph); Superconductivity (cond-mat.supr-con)

arXiv:2608.25645 [quant-ph]

(or arXiv:2608.25645v1 [quant-ph] for this version)

https://doi.org/10.48550/arXiv.2608.25645 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 253 words

Related coverage