This is a medical-imaging research paper where the core contribution is a learning-based model that adds clinical text, dose, and prior-registration history to deformable image registration. The reported gains are large on internal and external cohorts, but the clinical evidence rests on a blinded review of only 20 longitudinal cases and a single controlled dose benchmark, so generalization is still unproven. For AI readers, the takeaway is the design choice of conditioning registration on patient-specific trajectories and domain context rather than treating each image pair independently.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Personalising Deformable Image Registration with Clinical Context and Deformation History for Adaptive Radiotherapy

arXiv2 min read

arXiv:2610.18926v1 Announce Type: cross Abstract: Adaptive radiotherapy must account for anatomical changes during treatment, but doing so depends on reliably mapping targets, organs at risk and dose across serial images. Existing registration methods treat each image pair independently, without using radiotherapy-specific context or the patient's preceding anatomical trajectory. We developed Clinical-context-Aware and Patient-adaptive Deformable Image Registration (CAP-DIR), integrating source contours, dose, clinical text and prior-registration features. We evaluated 16,361 CT examinations from 3,473 patients across four institutional cohorts and five public benchmarks. CAP-DIR increased internal-test organ-at-risk-region normalized cross-correlation from 84.76% to 96.92% relative to the strongest learning-based comparator, with low deformation folding, and remained superior across seven external cohorts. In a blinded review of 20 longitudinal cases, clinically acceptable contours increased from 45.0% to 82.5% for clinical target volumes and from 22.5% to 62.5% for organs at risk, while estimated editing time decreased. In a controlled benchmark, CAP-DIR reduced global dose-mapping error by 34.5% relative to the strongest comparator. These findings show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.

Authors:Caiwen Jiang, Songlin Zhao, Yuzhen Ding, Jia Mi, Samir H. Patel, Alexandra Bennett, Keldon K. Lin, Terence T. Sio, Jonathan B. Ashman, Lisa A. McGee, Jean-Claude M. Rwigema, William G. Rule, Sameer R. Keole, Sujay A. Vora, William W. Wong, Nathan Y. Yu, Michele Y. Halyard, Steven E. Schild, Safia K. Ahmed, Daniel J. Ma, Robert L. Foote, Michelle A. Neben Wittich, Thomas J. Whitaker, Haibo Lin, Dinggang Shen, Wei Liu

Abstract:Adaptive radiotherapy must account for anatomical changes during treatment, but doing so depends on reliably mapping targets, organs at risk and dose across serial images. Existing registration methods treat each image pair independently, without using radiotherapy-specific context or the patient's preceding anatomical trajectory. We developed Clinical-context-Aware and Patient-adaptive Deformable Image Registration (CAP-DIR), integrating source contours, dose, clinical text and prior-registration features. We evaluated 16,361 CT examinations from 3,473 patients across four institutional cohorts and five public benchmarks. CAP-DIR increased internal-test organ-at-risk-region normalized cross-correlation from 84.76% to 96.92% relative to the strongest learning-based comparator, with low deformation folding, and remained superior across seven external cohorts. In a blinded review of 20 longitudinal cases, clinically acceptable contours increased from 45.0% to 82.5% for clinical target volumes and from 22.5% to 62.5% for organs at risk, while estimated editing time decreased. In a controlled benchmark, CAP-DIR reduced global dose-mapping error by 34.5% relative to the strongest comparator. These findings show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.

27 pages, 7 figures and 6 tables. The submission includes Supplementary Information

Image and Video Processing (eess.IV); Artificial Intelligence (cs.AI)

arXiv:2610.18926 [eess.IV]

(or arXiv:2610.18926v1 [eess.IV] for this version)

https://doi.org/10.48550/arXiv.2610.18926 arXiv-issued DOI via DataCite (pending registration)