Skip to content
aiqbench takeMachine Learning

aiqbench analysis

This research introduces a novel architecture combining convolutional encoding with dual Swin Transformer branches to synthesize CT images from MRI data, addressing critical limitations in radiotherapy planning workflows. By effectively modeling both local anatomical details and long-range dependencies, the method achieves clinically acceptable dosimetric accuracy while eliminating unnecessary ionizing radiation exposure during patient scans.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Parallel Swin Transformer-Enhanced 3D MRI-to-CT Synthesis for MRI-Only Radiotherapy Planning

arXiv2 min read

arXiv:2602.05387v2 Announce Type: replace-cross Abstract: MRI provides superior soft tissue contrast without ionizing radiation; however, the absence of electron density information limits its direct use for dose calculation. As a result, current radiotherapy workflows rely on combined MRI and CT acquisitions, increasing registration uncertainty and procedural complexity. Synthetic CT generation enables MRI only planning but remains challenging due to nonlinear MRI-CT relationships and anatomical variability. We propose Parallel Swin Transformer-Enhanced Med2Transformer, a 3D architecture that integrates convolutional encoding with dual Swin Transformer branches to model both local anatomical detail and long-range contextual dependencies. Multi-scale shifted window attention with hierarchical feature aggregation improves anatomical fidelity. Experiments on public and clinical datasets demonstrate higher image similarity and improved geometric accuracy compared with baseline methods. Dosimetric evaluation shows clinically acceptable performance, with a mean target dose error of 1.69%. Code is available at: https://github.com/mobaidoctor/med2transformer.

Abstract:MRI provides superior soft tissue contrast without ionizing radiation; however, the absence of electron density information limits its direct use for dose calculation. As a result, current radiotherapy workflows rely on combined MRI and CT acquisitions, increasing registration uncertainty and procedural complexity. Synthetic CT generation enables MRI only planning but remains challenging due to nonlinear MRI-CT relationships and anatomical variability. We propose Parallel Swin Transformer-Enhanced Med2Transformer, a 3D architecture that integrates convolutional encoding with dual Swin Transformer branches to model both local anatomical detail and long-range contextual dependencies. Multi-scale shifted window attention with hierarchical feature aggregation improves anatomical fidelity. Experiments on public and clinical datasets demonstrate higher image similarity and improved geometric accuracy compared with baseline methods. Dosimetric evaluation shows clinically acceptable performance, with a mean target dose error of 1.69%. Code is available at: this https URL.

This preprint has been accepted for publication in the proceedings of the IEEE 23rd International Symposium on Biomedical Imaging (ISBI 2026). The final published version is available at this https URL. The copyright for this work has been transferred to IEEE

Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG)

arXiv:2602.05387 [cs.CV]

(or arXiv:2602.05387v2 [cs.CV] for this version)

https://doi.org/10.1109/ISBI61048.2026.11515734 DOI(s) linking to related resources

Full text under the publisher's open licence · 202 words

Related coverage