aiqbench analysis
This research identifies optimal initial quantum states, such as two-mode NOON states and squeezed vacuums, to maximize measurement precision in linearized cavity optomechanics. By deriving closed-form solutions for variance maximization, the study demonstrates how specific entangled configurations can achieve Heisenberg-limited sensitivity for estimating single-photon coupling. These findings provide a theoretical framework for enhancing quantum metrology protocols in systems subject to cavity loss and thermal noise.
Optimal initial states for quantum Fisher information in linearized cavity optomechanics
arXiv:2610.01417v1 Announce Type: new Abstract: We find the optimal initial states of a linearized cavity-optomechanical system for estimating the single-photon coupling by quantum Fisher information. In the red-detuned (beam-splitter) regime the interaction exchanges excitations between the two modes, and for pure inputs the Fisher information is four times the variance of the excitation-exchange operator, reducing the optimization to variance maximization with a closed-form solution. With the mechanical mode in a Fock state the probe is degenerate: any state saturating the photon-number constraint is optimal, and a Fock reference with many phonons enhances the per-photon sensitivity linearly. For an arbitrary fixed mechanical reference it becomes a phase-matched squeezed vacuum, from an exact bound on that coherence obtained by a Lagrange-dual argument. Jointly optimizing both modes at fixed total excitation number, the quantum Fisher information obeys a Heisenberg bound quadratic in the energy, saturated by equal superpositions of the two extremal eigenstates of the generator, equivalently a two-mode NOON state after a balanced beam splitter; balanced product Fock states reach only a linear enhancement. Exact diagonalization in truncated Fock spaces confirms all the results, the familiar single-photon input being the simplest saturating case. Three extensions are worked out: the blue sideband has an unbounded two-mode-squeezing spectrum, so the entangled optimum becomes impossible and the balanced product Fock state is exactly optimal at definite energy; under cavity loss the information accumulation turns linear on the cavity-lifetime timescale, at a renewal-optimal duration of about two and a half lifetimes; and for a state-of-the-art quantum-coherent coupling experiment the per-hour relative precision lies between one part in a million and ten parts in a million, number and thermal references being the most robust.
Abstract:We find the optimal initial states of a linearized cavity-optomechanical system for estimating the single-photon coupling by quantum Fisher information. In the red-detuned (beam-splitter) regime the interaction exchanges excitations between the two modes, and for pure inputs the Fisher information is four times the variance of the excitation-exchange operator, reducing the optimization to variance maximization with a closed-form solution. With the mechanical mode in a Fock state the probe is degenerate: any state saturating the photon-number constraint is optimal, and a Fock reference with many phonons enhances the per-photon sensitivity linearly. For an arbitrary fixed mechanical reference it becomes a phase-matched squeezed vacuum, from an exact bound on that coherence obtained by a Lagrange-dual argument. Jointly optimizing both modes at fixed total excitation number, the quantum Fisher information obeys a Heisenberg bound quadratic in the energy, saturated by equal superpositions of the two extremal eigenstates of the generator, equivalently a two-mode NOON state after a balanced beam splitter; balanced product Fock states reach only a linear enhancement. Exact diagonalization in truncated Fock spaces confirms all the results, the familiar single-photon input being the simplest saturating case. Three extensions are worked out: the blue sideband has an unbounded two-mode-squeezing spectrum, so the entangled optimum becomes impossible and the balanced product Fock state is exactly optimal at definite energy; under cavity loss the information accumulation turns linear on the cavity-lifetime timescale, at a renewal-optimal duration of about two and a half lifetimes; and for a state-of-the-art quantum-coherent coupling experiment the per-hour relative precision lies between one part in a million and ten parts in a million, number and thermal references being the most robust.
arXiv:2610.01417 [quant-ph]
(or arXiv:2610.01417v1 [quant-ph] for this version)
https://doi.org/10.48550/arXiv.2610.01417 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 363 words
Related coverage

Researchers Bound Sensitivity with NOON States in Optomechanics
Quantum Zeitgeist · Oct 4, 2026
Gravitational acceleration encoded in Jaynes Cummings exchange frequencies: Quantum Fisher information, readout, and validity conditions
arXiv · Jul 28, 2026

Quantum Sensor’s Sensitivity Boosted by Multibody Interactions
Quantum Zeitgeist · Oct 15, 2026

News
Quantum Computing Report · Jul 25, 2026