aiqbench analysis
This research introduces a novel federated learning framework specifically designed for segmenting catheters and guidewires in X-ray fluoroscopy, addressing critical data privacy and scarcity issues in endovascular procedures. By integrating shape-sensitive losses and adversarial optimization within a distributed training setup, the method significantly improves segmentation accuracy without centralizing sensitive patient data. The work also leverages synthetic data generation to enhance model robustness across heterogeneous institutional environments.
Novel Methods for Catheter and Guidewire Segmentation in X-ray Fluoroscopy under a Federated Learning Setting
arXiv:2609.06876v1 Announce Type: cross Abstract: Endovascular procedures rely on real-time manipulation of thin instruments, catheters and guidewires, under X-ray fluoroscopy guidance, where accurate visual analysis is essential for procedural safety. Learning-based methods are constrained by structural complexity, data scarcity, and privacy regulations precluding centralised training across institutions. This thesis presents a structure-aware federated learning framework for catheter and guidewire analysis, with four contributions evaluated on real-animal and phantom data. A benchmark dataset, CathAction, is introduced for catheterisation analysis, with over 600,000 annotated frames and 40,000 segmentation masks. A shape-sensitive loss transforms masks into signed distance maps compared in a structural feature space, improving Dice coefficient by up to 2.9 points across five backbones. This is extended to federated learning with shape-sensitive loss, preserving geometric consistency under heterogeneous client data and outperforming federated averaging by up to three points in mean intersection-over-union as clients scale from four to eight. Federated learning with projected gradient descent adds adversarial optimisation, raising mean intersection-over-union by over ten points on real-animal data. Finally, a structure-aware diffusion framework synthesises catheter and guidewire video sequences, combining structural supervision with a domain-adaptive reconstruction objective, reducing Frechet video distance over a strong baseline while maintaining visual fidelity. Incorporating synthetic sequences into federated training raises the Dice score from 44 to 51 percent under data scarcity, with gains across four held-out sites. Together, these contributions advance privacy-preserving catheter and guidewire analysis, supporting collaborative training without centralising patient data or large amounts of manual annotation.
Abstract:Endovascular procedures rely on real-time manipulation of thin instruments, catheters and guidewires, under X-ray fluoroscopy guidance, where accurate visual analysis is essential for procedural safety. Learning-based methods are constrained by structural complexity, data scarcity, and privacy regulations precluding centralised training across institutions. This thesis presents a structure-aware federated learning framework for catheter and guidewire analysis, with four contributions evaluated on real-animal and phantom data. A benchmark dataset, CathAction, is introduced for catheterisation analysis, with over 600,000 annotated frames and 40,000 segmentation masks. A shape-sensitive loss transforms masks into signed distance maps compared in a structural feature space, improving Dice coefficient by up to 2.9 points across five backbones. This is extended to federated learning with shape-sensitive loss, preserving geometric consistency under heterogeneous client data and outperforming federated averaging by up to three points in mean intersection-over-union as clients scale from four to eight. Federated learning with projected gradient descent adds adversarial optimisation, raising mean intersection-over-union by over ten points on real-animal data. Finally, a structure-aware diffusion framework synthesises catheter and guidewire video sequences, combining structural supervision with a domain-adaptive reconstruction objective, reducing Frechet video distance over a strong baseline while maintaining visual fidelity. Incorporating synthetic sequences into federated training raises the Dice score from 44 to 51 percent under data scarcity, with gains across four held-out sites. Together, these contributions advance privacy-preserving catheter and guidewire analysis, supporting collaborative training without centralising patient data or large amounts of manual annotation.
PhD Thesis, University of Liverpool. 163 pages
Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)
arXiv:2609.06876 [cs.CV]
(or arXiv:2609.06876v1 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2609.06876 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 346 words
Related coverage

Developing Healthcare Robotics with GPU-Native Medical Physics Simulation
NVIDIA · Jul 28, 2026

Tariffs didn’t bring manufacturing jobs back to the US
The Verge · Jul 27, 2026

News
Quantum Computing Report · Jul 25, 2026
Federated Medical Image Segmentation under Real-World Label Noise: A Benchmark Suite for Noisy Label Learning Method Selection
arXiv · Jun 16, 2026