aiqbench analysis

This research demonstrates the viability of using deep learning models on wrist-worn accelerometers for non-invasive seizure detection, achieving high sensitivity with minimal false alarms. By leveraging time-series ResNet architectures, the study offers a scalable alternative to intrusive hospital-based monitoring and unreliable patient diaries. The work highlights significant progress in applying AI to improve long-term ambulatory care for epilepsy patients.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Non-invasive Seizure Detection Using Wearable Wrist-worn Accelerometry and Deep Learning

arXiv3 min read

arXiv:2610.05919v1 Announce Type: cross Abstract: Seizure monitoring and detection are crucial for reducing the morbidity and mortality associated with seizures. Current epilepsy care, often involving expensive video-electroencephalography (VEEG) monitoring, requires specialized expertise and is limited to in-hospital settings, and intrusive in nature. Seizure diaries, on the other hand, suffer from unreliability due to under-reporting, leading to incorrect therapeutic decisions. Wearable non-invasive seizure detection may offer a more tolerable and feasible solution for long-term ambulatory monitoring. This study explores a wearable remote monitoring system utilizing a single wrist-worn accelerometer device and capable of detecting multiple types of seizures, including shorter duration events. We enrolled 79 patients under video-electroencephalography monitoring to wear accelerometer devices and collect data. Concurrent VEEG recordings were reviewed by board-certified epileptologists to produce annotations, including seizure onset, offset, and seizure type. Using this data, we constructed a deep neural network based on the time-series ResNet architecture, which could discriminate among seizure and non-seizure events. Our proposed approach achieved a seizure detection sensitivity of 95.65% and an overall false alarm rate of 0.15/24 hours during the evaluation, which spanned 5576 hours of total recording. Additionally, it resulted in an area under the receiver operating characteristic curve (AUC-ROC) of 0.98 and an area under the precision-re call curve (AUC-PRC) of 0.67 when averaged over 20 patients who experienced 46 convulsive seizures. These promising results suggest that the proposed seizure detection system can be effectively used for long-term ambulatory seizure monitoring. Future steps include validating our findings in larger datasets and assessing the utility of detection for additional seizure types.

Abstract:Seizure monitoring and detection are crucial for reducing the morbidity and mortality associated with seizures. Current epilepsy care, often involving expensive video-electroencephalography (VEEG) monitoring, requires specialized expertise and is limited to in-hospital settings, and intrusive in nature. Seizure diaries, on the other hand, suffer from unreliability due to under-reporting, leading to incorrect therapeutic decisions. Wearable non-invasive seizure detection may offer a more tolerable and feasible solution for long-term ambulatory monitoring. This study explores a wearable remote monitoring system utilizing a single wrist-worn accelerometer device and capable of detecting multiple types of seizures, including shorter duration events. We enrolled 79 patients under video-electroencephalography monitoring to wear accelerometer devices and collect data. Concurrent VEEG recordings were reviewed by board-certified epileptologists to produce annotations, including seizure onset, offset, and seizure type. Using this data, we constructed a deep neural network based on the time-series ResNet architecture, which could discriminate among seizure and non-seizure events. Our proposed approach achieved a seizure detection sensitivity of 95.65% and an overall false alarm rate of 0.15/24 hours during the evaluation, which spanned 5576 hours of total recording. Additionally, it resulted in an area under the receiver operating characteristic curve (AUC-ROC) of 0.98 and an area under the precision-re call curve (AUC-PRC) of 0.67 when averaged over 20 patients who experienced 46 convulsive seizures. These promising results suggest that the proposed seizure detection system can be effectively used for long-term ambulatory seizure monitoring. Future steps include validating our findings in larger datasets and assessing the utility of detection for additional seizure types.

Machine Learning (cs.LG); Artificial Intelligence (cs.AI)

arXiv:2610.05919 [cs.LG]

(or arXiv:2610.05919v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2610.05919 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 351 words