aiqbench analysis
This research applies deep residual neural networks within a simulation environment to predict minimum distances between robotic arms, enabling early collision warnings for multi-arm laparoscopic surgery systems. By integrating analytical modeling with machine learning, the framework achieves high predictive accuracy (R² = 0.94) and ensures safe operational clearance without relying solely on theoretical calculations. The study highlights how AI-driven inference can enhance safety protocols in complex robotic surgical workflows where traditional methods may fall short of real-time precision requirements.
Neural Minimum-Distance Estimation for Collision-Aware Operation of Multi-Arm Laparoscopy Surgical Robots Through Learning-from-Simulation
arXiv:2601.15459v2 Announce Type: replace Abstract: This study presents an integrated framework for enhancing the safety and operational efficiency of robotic arms in laparoscopic surgery by addressing minimum distance estimation between multi-arm manipulators and the associated collision-aware warning. By combining analytical modeling, real time simulation, and machine learning, the framework offers a robust solution for ensuring safe robotic operations. An analytical model was developed to estimate the minimum distances between robotic arms based on their joint configurations, offering theoretical calculations that serve as both a validation tool and a benchmark. To complement this, a 3D simulation environment was created to model two 7 DOF Kinova robotic arms (Kinova inc., Boisbriand, QC, Canada), generating a diverse dataset of configurations for distance estimation and collision warning. Using these insights, a deep residual neural network model was trained with joint configurations as inputs. On the held out validation set, the model achieves R2 = 0.940, RMSE = 42.0 mm, MAE = 28.7 mm, and a near zero mean bias, demonstrating strong predictive accuracy and consistent generalization across the workspace. The framework is intended as an early collision warning layer, where a warning is triggered when the predicted inter-arm distance falls below a 0.2 m threshold, which corresponds to a surface to surface clearance of approximately 50 mm given the Kinova Gen3 (Kinova inc., Boisbriand, QC, Canada) cross sectional radius. This work demonstrates the effectiveness of combining analytical modeling with machine learning to enhance the precision and reliability of multi-arm robotic systems.
Abstract:This study presents an integrated framework for enhancing the safety and operational efficiency of robotic arms in laparoscopic surgery by addressing minimum distance estimation between multi-arm manipulators and the associated collision-aware warning. By combining analytical modeling, real time simulation, and machine learning, the framework offers a robust solution for ensuring safe robotic operations. An analytical model was developed to estimate the minimum distances between robotic arms based on their joint configurations, offering theoretical calculations that serve as both a validation tool and a benchmark. To complement this, a 3D simulation environment was created to model two 7 DOF Kinova robotic arms (Kinova inc., Boisbriand, QC, Canada), generating a diverse dataset of configurations for distance estimation and collision warning. Using these insights, a deep residual neural network model was trained with joint configurations as inputs. On the held out validation set, the model achieves R2 = 0.940, RMSE = 42.0 mm, MAE = 28.7 mm, and a near zero mean bias, demonstrating strong predictive accuracy and consistent generalization across the workspace. The framework is intended as an early collision warning layer, where a warning is triggered when the predicted inter-arm distance falls below a 0.2 m threshold, which corresponds to a surface to surface clearance of approximately 50 mm given the Kinova Gen3 (Kinova inc., Boisbriand, QC, Canada) cross sectional radius. This work demonstrates the effectiveness of combining analytical modeling with machine learning to enhance the precision and reliability of multi-arm robotic systems.
Robotics (cs.RO)
arXiv:2601.15459 [cs.RO]
(or arXiv:2601.15459v2 [cs.RO] for this version)
https://doi.org/10.48550/arXiv.2601.15459 Focus to learn more arXiv-issued DOI via DataCite
https://doi.org/10.3390/s26123744 Focus to learn more DOI(s) linking to related resources
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 343 words
Related coverage
Worst-Case Distance-Aware Error Bounds for Neural Networks
arXiv · Aug 7, 2026

The Machines that Make the Machines
NVIDIA · Oct 7, 2026

[AINews] Reality Checks on AI News (Yegge shuts down Gas Town, Databricks’ +60% Astra cost)
Latent Space · Sep 17, 2026

Lattice-Based Cryptography Explained
Quantum Zeitgeist · Aug 15, 2026