aiqbench analysis
The paper shows that LLM-as-judge safety evaluations are less deterministic than commonly assumed. Setting temperature to 0 reduces but does not eliminate verdict flips on borderline items, and newer models have removed the temperature control entirely. For readers who rely on single-run safety scores to gate deployment, the practical takeaway is to report grader disagreement and variance alongside pass/fail results.
Necessary but Not Sufficient: Temperature Control and Reproducibility in LLM-as-Judge Safety Evaluations
arXiv:2606.26185v2 Announce Type: replace Abstract: LLM-as-judge ("grader") components are now standard in evaluation harnesses, including safety evaluations where a pass/fail verdict may gate downstream deployment decisions. A widespread assumption is that setting the grader's sampling temperature to 0 makes grading deterministic. We test this assumption against a real safety-evaluation codebase (Japan AISI's open-source aisev) and show it fails on two levels. First, the harness invokes its grader without setting temperature or seed; the underlying provider silently applies its default of 1.0, so items near the decision boundary flip pass/fail across identical runs (per-item disagreement up to ~50% over 20 runs). Second, pinning temperature=0 reduces but does not eliminate flips: across 690 API calls spanning two providers, three model tiers, and five sampling configurations, 1-2 of 7 borderline items remain non-reproducible even under forced greedy decoding (top_k=1). Claude Opus 4.7/4.8 has since deprecated temperature entirely, rendering the primary mitigation inapplicable to newer model generations. These findings expose a structural gap: evaluation harnesses that report single-run verdicts without variance or grader-disagreement metrics can present noise as a safety property. We release a reproduction harness (690 calls, 7 conditions) and recommend that harnesses treat grader disagreement as a first-class health metric alongside the scores themselves.
Abstract:LLM-as-judge ("grader") components are now standard in evaluation harnesses, including safety evaluations where a pass/fail verdict may gate downstream deployment decisions. A widespread assumption is that setting the grader's sampling temperature to 0 makes grading deterministic. We test this assumption against a real safety-evaluation codebase (Japan AISI's open-source aisev) and show it fails on two levels. First, the harness invokes its grader without setting temperature or seed; the underlying provider silently applies its default of 1.0, so items near the decision boundary flip pass/fail across identical runs (per-item disagreement up to ~50% over 20 runs). Second, pinning temperature=0 reduces but does not eliminate flips: across 690 API calls spanning two providers, three model tiers, and five sampling configurations, 1-2 of 7 borderline items remain non-reproducible even under forced greedy decoding (top_k=1). Claude Opus 4.7/4.8 has since deprecated temperature entirely, rendering the primary mitigation inapplicable to newer model generations. These findings expose a structural gap: evaluation harnesses that report single-run verdicts without variance or grader-disagreement metrics can present noise as a safety property. We release a reproduction harness (690 calls, 7 conditions) and recommend that harnesses treat grader disagreement as a first-class health metric alongside the scores themselves.
Machine Learning (cs.LG)
arXiv:2606.26185 [cs.LG]
(or arXiv:2606.26185v2 [cs.LG] for this version)
https://doi.org/10.48550/arXiv.2606.26185 Focus to learn more arXiv-issued DOI via DataCite
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 289 words
Related coverage
Temperature and reproducibility in photocatalysis
Nature · Sep 22, 2026
The Necessity of Setting Temperature in LLM-as-a-Judge
arXiv · Jun 8, 2026
Quantum computation of energy level degeneracy and thermodynamical properties of spin systems
arXiv · Oct 27, 2026
Anderson orthogonality scaling in the Rabi-driven heavy Fermi polaron
arXiv · Sep 9, 2026