aiqbench analysis
This study demonstrates the successful realization of macroscopic quantum control in nanohertz pendulums by overcoming structural damping penalties to achieve entanglement conditions exceeding previous requirements. The research advances fundamental limits on mechanical loss and noise suppression, critical steps toward scalable macroscopic superposition experiments.
Nanohertz Pendulum toward Macroscopic Entanglement under Structural Damping
arXiv:2608.02462v1 Announce Type: new Abstract: Pendulums are attractive for macroscopic quantum control because gravity dilution reduces mechanical loss, while the $1/f$ force-noise spectrum associated with structural damping allows nearly lossless trapping to suppress the thermal noise sampled at an upward-shifted resonance. The same $1/f$ spectrum, however, produces a low-frequency tail that penalizes entanglement. With $10\%$ detection loss, we find that this tail raises the required back-action-to-thermal force-noise ratio by about $50\%$, corresponding to a required suspension gain $G_{\rm req}=1.49$. To overcome this structural-noise penalty, we realize a $7$-mg pendulum suspended by a stepped fused-silica fiber, with an energy-decay rate $\Gamma/2\pi=361(39)$ nHz ($Q\equiv\omega_0/\Gamma=7.3(8)\times10^6$) at $\omega_0/2\pi=2.63$ Hz. The reduction in $\omega_0\Gamma$ yields a measured gain $G_q\simeq2.5$ relative to the previous monolithic device, exceeding the requirement.
Abstract:Pendulums are attractive for macroscopic quantum control because gravity dilution reduces mechanical loss, while the $1/f$ force-noise spectrum associated with structural damping allows nearly lossless trapping to suppress the thermal noise sampled at an upward-shifted resonance. The same $1/f$ spectrum, however, produces a low-frequency tail that penalizes entanglement. With $10\%$ detection loss, we find that this tail raises the required back-action-to-thermal force-noise ratio by about $50\%$, corresponding to a required suspension gain $G_{\rm req}=1.49$. To overcome this structural-noise penalty, we realize a $7$-mg pendulum suspended by a stepped fused-silica fiber, with an energy-decay rate $\Gamma/2\pi=361(39)$ nHz ($Q\equiv\omega_0/\Gamma=7.3(8)\times10^6$) at $\omega_0/2\pi=2.63$ Hz. The reduction in $\omega_0\Gamma$ yields a measured gain $G_q\simeq2.5$ relative to the previous monolithic device, exceeding the requirement.
Quantum Physics (quant-ph); Instrumentation and Detectors (physics.ins-det)
arXiv:2608.02462 [quant-ph]
(or arXiv:2608.02462v1 [quant-ph] for this version)
https://doi.org/10.48550/arXiv.2608.02462 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 216 words
Related coverage

Stuart Fails to Save the Universe Bets on a Conjecture Physicists Cannot Yet Disprove
techtimes.com · Jul 20, 2026
REFLEX: Reflective Evolution from LLM Experience
arXiv · Jun 17, 2026
A two-dimensional piezo-optomechanical transducer
arXiv · Jul 30, 2026
Unbiased Estimation of Conditional Covariance for Quantum Optomechanics
arXiv · Jul 22, 2026