Skip to content
aiqbench takeQuantum Comms

aiqbench analysis

This research demonstrates a significant leap in nanoscale thermometry by leveraging isotopically purified nitrogen-vacancy centers within nanodiamonds to achieve sub-millikelvin resolution. By utilizing a bespoke quantum sensing chip, the team overcomes previous limitations of short coherence times and low photon counts, enabling precise monitoring of transient thermal events at the nanometer scale. This advancement opens new avenues for studying minute heat fluctuations in living biological systems and evaluating catalyst performance with unprecedented accuracy.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Microkelvin resolution thermometry at the nanometre scale

arXiv2 min read

arXiv:2609.04907v1 Announce Type: new Abstract: Accurate temperature readings of transient events at the nanometer scale are challenging due to the low sensitivity of available sensors. Nanodiamonds containing nitrogen-vacancy (NV) centers have been used for nanoscale thermometry in complex environments, including inside living cells. However, their performance has been limited by short coherence times and low photon counts. In this work, we use isotopically-purified dual-NV nanodiamonds and a bespoke quantum sensing chip to showcase an order of magnitude improvement in temperature measurement sensitivity compared with previous reports. We demonstrate robust temperature measurements with an error of 682 $\mu$K, experimental sensitivities below 50 mK/$\surd \text{Hz}$ and a shot-noise limited sensitivity of 9.6 mK/$\surd \text{Hz}$. To confirm the utility of these high-performance nanothermometers, we quantify the temperature change induced by the thermometry measurement itself, specifically the optical excitation laser used to probe the NV spin state. In addition, we observe directly at the nanometre scale the transient heating caused by the exothermic mixing of dimethyl sulfoxide in water. Sub-millikelvin resolution and millikelvin sensitivity thermometry unlock the possibility of monitoring minute thermal fluctuations in living systems and assessing catalyst performance at the nanometre scale.

Authors:Jack W. Hart, Soham Pal, Julien R. E. Roth, Katie Ninham, Abbie H. Aleksandrova, Xander Peetroons, Soumen Mandal, Oliver A. Williams, Gavin W. Morley, Mete Atature, Helena S. Knowles

Abstract:Accurate temperature readings of transient events at the nanometer scale are challenging due to the low sensitivity of available sensors. Nanodiamonds containing nitrogen-vacancy (NV) centers have been used for nanoscale thermometry in complex environments, including inside living cells. However, their performance has been limited by short coherence times and low photon counts. In this work, we use isotopically-purified dual-NV nanodiamonds and a bespoke quantum sensing chip to showcase an order of magnitude improvement in temperature measurement sensitivity compared with previous reports. We demonstrate robust temperature measurements with an error of 682 $\mu$K, experimental sensitivities below 50 mK/$\surd \text{Hz}$ and a shot-noise limited sensitivity of 9.6 mK/$\surd \text{Hz}$. To confirm the utility of these high-performance nanothermometers, we quantify the temperature change induced by the thermometry measurement itself, specifically the optical excitation laser used to probe the NV spin state. In addition, we observe directly at the nanometre scale the transient heating caused by the exothermic mixing of dimethyl sulfoxide in water. Sub-millikelvin resolution and millikelvin sensitivity thermometry unlock the possibility of monitoring minute thermal fluctuations in living systems and assessing catalyst performance at the nanometre scale.

Quantum Physics (quant-ph); Applied Physics (physics.app-ph); Instrumentation and Detectors (physics.ins-det)

arXiv:2609.04907 [quant-ph]

(or arXiv:2609.04907v1 [quant-ph] for this version)

https://doi.org/10.48550/arXiv.2609.04907 arXiv-issued DOI via DataCite (pending registration)

Full text under the publisher's open licence · 239 words

Related coverage