MedSegBenchmarker introduces a rigorous framework to address reproducibility issues in medical image segmentation by standardizing data splitting, preprocessing, and metric aggregation protocols. The tool demonstrates that minor variations in experimental setup can significantly alter model rankings, highlighting the necessity for explicit evaluation conditions in machine learning research. This work directly advances the field of Machine Learning by providing essential infrastructure for fair and comparable benchmarking across heterogeneous datasets.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

MedSegBenchmarker: A Raw-Count-First Framework for Controlled 2D Medical Image Segmentation Benchmarks

arXiv3 min read

arXiv:2608.29677v1 Announce Type: cross Abstract: Despite rapid advances in MIS, fair and reproducible comparisons of segmentation models remain challenging due to heterogeneous datasets, inconsistent evaluation protocols, and rapidly evolving architectures. In particular, comparisons often implicitly assume that model rankings are invariant to data partitioning, preprocessing, metric aggregation, uncertainty estimation, and computational constraints. The lack of extensible and unified evaluation frameworks further limits systematic investigation of new models, datasets, and training paradigms. We present MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS. It integrates duplicate and near-duplicate image detection, group-aware data splitting, YAML study specifications, resumable training, hyperparameter optimization, cross-validation, and checkpoint-based evaluation. Rather than retaining only aggregate performance measures, MSB exports sample- and class-level pixel counts and predictions together with the evaluation context. These elementary artifacts enable post-hoc analyses without repeated inference. We demonstrate MSB in a case study involving three heterogeneous 2D datasets and multiple MIS and general-purpose vision models evaluated at 256- and 512-pixel input resolutions. Reaggregation of identical predictions changes the top-ranked architecture in three of six dataset-resolution settings, despite high rank correlations between aggregation strategies. Increasing input resolution produces model- and dataset-dependent performance gains and losses that must be considered alongside empirically measured inference complexity. These results show that seemingly minor choices in evaluation and experimental setup can affect benchmark conclusions. MSB, available at GitHub, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.

Abstract:Despite rapid advances in MIS, fair and reproducible comparisons of segmentation models remain challenging due to heterogeneous datasets, inconsistent evaluation protocols, and rapidly evolving architectures. In particular, comparisons often implicitly assume that model rankings are invariant to data partitioning, preprocessing, metric aggregation, uncertainty estimation, and computational constraints. The lack of extensible and unified evaluation frameworks further limits systematic investigation of new models, datasets, and training paradigms. We present MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS. It integrates duplicate and near-duplicate image detection, group-aware data splitting, YAML study specifications, resumable training, hyperparameter optimization, cross-validation, and checkpoint-based evaluation. Rather than retaining only aggregate performance measures, MSB exports sample- and class-level pixel counts and predictions together with the evaluation context. These elementary artifacts enable post-hoc analyses without repeated inference. We demonstrate MSB in a case study involving three heterogeneous 2D datasets and multiple MIS and general-purpose vision models evaluated at 256- and 512-pixel input resolutions. Reaggregation of identical predictions changes the top-ranked architecture in three of six dataset-resolution settings, despite high rank correlations between aggregation strategies. Increasing input resolution produces model- and dataset-dependent performance gains and losses that must be considered alongside empirically measured inference complexity. These results show that seemingly minor choices in evaluation and experimental setup can affect benchmark conclusions. MSB, available at GitHub, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)

arXiv:2608.29677 [cs.CV]

(or arXiv:2608.29677v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2608.29677 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 333 words

Related coverage