aiqbench analysis
This paper introduces MedPsy, a pair of small (1.7B and 4B parameter) medical language models built for on-device use. Its reported gains come from a synthetic data pipeline, staged SFT and RL post-training, and edge benchmarks. The results are self-reported on seven closed-ended medical benchmarks and HealthBench-Hard, so independent replication matters before treating the comparisons to MedGemma as settled. Readers interested in edge AI should note the efficiency claims: shorter reasoning traces, quantization that keeps accuracy within about 1 point, and under 5 GB peak RAM on laptops and phones.
MedPsy: State-of-the-Art Small Medical Language Models for Efficient Edge Deployment
arXiv:2611.02011v1 Announce Type: new Abstract: Medical language models promise expert clinical support, but the strongest open-source LLMs remain too large for private edge-device deployment, while compact medical models still trail substantially on knowledge-intensive and real-world healthcare tasks. Reasoning models that fit edge memory budgets can produce long reasoning traces, increasing sequential decoding, end-to-end latency, energy consumption, and KV-cache memory pressure. We present MedPsy, a family of text-only 1.7B and 4B medical language models designed for edge deployment, targeting this accuracy-generation-efficiency trade-off. Our recipe combines a synthetic medical data pipeline over biology, medicine, and health seeds with chain-of-thought targets from a 235B medical-focused LLM teacher; a four-stage post-training curriculum comprising two SFT stages followed by two RL stages with hard-sample mining; and an edge deployment evaluation spanning multiple GGUF quantization variants and real-device inference on laptop and smartphone hardware. On seven closed-ended medical benchmarks, MedPsy-4B surpasses MedGemma-1.5-4B by 19.34 points and matches MedGemma-27B while being 6.75x smaller; MedPsy-1.7B outperforms MedGemma-1.5-4B by 11.42 points despite being less than half its size. On HealthBench-Hard, MedPsy-4B surpasses MedGemma-27B by 15.33 points, while MedPsy-1.7B surpasses it by 11.66 points despite being ~16x smaller. Beyond accuracy, MedPsy reduces average response length by 1.7x (1.7B) and 3.2x (4B) versus its Qwen3 backbones, while Q4_K_M quantization preserves the aggregate score within 1 point of BF16 with ~69% lower disk footprint. In real-device inference, MedPsy-4B's shorter generations translate into 75% lower median end-to-end latency and estimated energy per answer than its Qwen3 backbone at matched quantization, while peak RAM remains below 5 GB across our tested laptop and smartphone configurations.
Abstract:Medical language models promise expert clinical support, but the strongest open-source LLMs remain too large for private edge-device deployment, while compact medical models still trail substantially on knowledge-intensive and real-world healthcare tasks. Reasoning models that fit edge memory budgets can produce long reasoning traces, increasing sequential decoding, end-to-end latency, energy consumption, and KV-cache memory pressure. We present MedPsy, a family of text-only 1.7B and 4B medical language models designed for edge deployment, targeting this accuracy-generation-efficiency trade-off. Our recipe combines a synthetic medical data pipeline over biology, medicine, and health seeds with chain-of-thought targets from a 235B medical-focused LLM teacher; a four-stage post-training curriculum comprising two SFT stages followed by two RL stages with hard-sample mining; and an edge deployment evaluation spanning multiple GGUF quantization variants and real-device inference on laptop and smartphone hardware. On seven closed-ended medical benchmarks, MedPsy-4B surpasses MedGemma-1.5-4B by 19.34 points and matches MedGemma-27B while being 6.75x smaller; MedPsy-1.7B outperforms MedGemma-1.5-4B by 11.42 points despite being less than half its size. On HealthBench-Hard, MedPsy-4B surpasses MedGemma-27B by 15.33 points, while MedPsy-1.7B surpasses it by 11.66 points despite being ~16x smaller. Beyond accuracy, MedPsy reduces average response length by 1.7x (1.7B) and 3.2x (4B) versus its Qwen3 backbones, while Q4_K_M quantization preserves the aggregate score within 1 point of BF16 with ~69% lower disk footprint. In real-device inference, MedPsy-4B's shorter generations translate into 75% lower median end-to-end latency and estimated energy per answer than its Qwen3 backbone at matched quantization, while peak RAM remains below 5 GB across our tested laptop and smartphone configurations.
Computation and Language (cs.CL)
arXiv:2611.02011 [cs.CL]
(or arXiv:2611.02011v1 [cs.CL] for this version)
https://doi.org/10.48550/arXiv.2611.02011 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 351 words