MedForj establishes a new benchmark in medical imaging by leveraging large-scale diffusion models to generate high-fidelity 3D brain MRI priors from over 72,000 curated volumes. The study demonstrates that flow matching offers the most robust performance across diverse inverse problems and segmentation tasks, providing researchers with open weights and code to accelerate reconstruction workflows. This work advances the application of generative AI in healthcare by offering a versatile foundation model specifically tuned for anatomical accuracy and data efficiency.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

MedForj: An open, large-scale foundational generative prior for high-resolution 3D brain MRI

arXiv3 min read

arXiv:2510.26834v2 Announce Type: replace-cross Abstract: This work introduces MedForj, a suite of 3D foundational generative priors based on diffusion models. The MedForj models were trained on $72{,}659$ 1~mm isotropic 3D $T_1$-weighted MRI human brain image volumes from $38{,}174$ subjects, drawn from a curated corpus of $80{,}675$ volumes from $42{,}506$ subjects spanning $38$ publicly available datasets. These training images were manually inspected to exclude those with poor quality and excessive pathology, and otherwise were minimally processed. The models include six different diffusion training strategies: rectified flow, latent diffusion rectified flow, flow matching, velocity prediction, clean prediction, and noise prediction. Image samples produced by each of these models were compared to each other and against real, ground truth data under downstream segmentation distributions, FID, five inverse problems, and blind human inspection in an observer study. Flow matching was the strongest strategy overall, achieving the best inverse problem solving results at $28.80$~dB PSNR and $0.874$ SSIM averaged over the five forward problems, the highest rate of reconstructions judged real by blind human raters at $72.6\%$, and the closest per-structure match to real segmented anatomy in a permutation test. It was not best everywhere: rectified flow produced the most convincing unconditional samples in the observer study and the best FID, and the latent rectified-flow model achieved the smallest joint distributional distance to real anatomy. No other strategy, however, performed consistently well across all four evaluations. We therefore recommend flow matching as the default MedForj prior, while releasing every strategy so that the choice can be revisited per application. All model weights and corresponding code are publicly available at https://github.com/piksl-research/medforj.

Abstract:This work introduces MedForj, a suite of 3D foundational generative priors based on diffusion models. The MedForj models were trained on $72{,}659$ 1~mm isotropic 3D $T_1$-weighted MRI human brain image volumes from $38{,}174$ subjects, drawn from a curated corpus of $80{,}675$ volumes from $42{,}506$ subjects spanning $38$ publicly available datasets. These training images were manually inspected to exclude those with poor quality and excessive pathology, and otherwise were minimally processed. The models include six different diffusion training strategies: rectified flow, latent diffusion rectified flow, flow matching, velocity prediction, clean prediction, and noise prediction. Image samples produced by each of these models were compared to each other and against real, ground truth data under downstream segmentation distributions, FID, five inverse problems, and blind human inspection in an observer study. Flow matching was the strongest strategy overall, achieving the best inverse problem solving results at $28.80$~dB PSNR and $0.874$ SSIM averaged over the five forward problems, the highest rate of reconstructions judged real by blind human raters at $72.6\%$, and the closest per-structure match to real segmented anatomy in a permutation test. It was not best everywhere: rectified flow produced the most convincing unconditional samples in the observer study and the best FID, and the latent rectified-flow model achieved the smallest joint distributional distance to real anatomy. No other strategy, however, performed consistently well across all four evaluations. We therefore recommend flow matching as the default MedForj prior, while releasing every strategy so that the choice can be revisited per application. All model weights and corresponding code are publicly available at this https URL.

Image and Video Processing (eess.IV); Artificial Intelligence (cs.AI)

arXiv:2510.26834 [eess.IV]

(or arXiv:2510.26834v2 [eess.IV] for this version)

https://doi.org/10.48550/arXiv.2510.26834 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.