Skip to content
aiqbench takeAI Products

aiqbench analysis

CLEAR-Med introduces a dual-agent architecture that separates SQL generation from independent validation, significantly improving accuracy on structured clinical data compared to ungrounded LLM baselines. By enforcing deterministic checks and allowing the system to fail closed on unresolved cases, this framework offers a robust path toward traceable AI analysis in high-stakes medical environments.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Large Language Models for Structured Clinical Data Analysis: Dual-Agent Grounding and Validation

arXiv3 min read

arXiv:2609.34039v1 Announce Type: new Abstract: Objective: To develop and characterize CLEAR-Med, a dual-agent framework for natural-language analysis of structured clinical data that separates SQL-based invocation from independent validation. Methods: CLEAR-Med uses one agent to translate a question into executable Structured Query Language (SQL), retain the executed query and database result, and produce a draft. Deterministic checks and a separately invoked cross-provider Validation Agent then accept the draft, request one bounded repair, or abstain. We formalized the system as a bounded selective pipeline and evaluated CLEAR-Med's configuration and scalability, and the Invocation Agent's accuracy and consistency on a 25-query development benchmark, using a harmonized 21-site neonatal hypoxic-ischemic encephalopathy table containing 532 de-identified infant records and approximately 1,300 variables. Results: CLEAR-Med completed all six nominal scalability configurations, including 500x1300. Across 25 development-benchmark queries repeated five times, the Invocation Agent answered 83 of 125 responses correctly (66.4%; query-cluster bootstrap 95% CI, 48.0-83.2%), compared with 15 of 125 (12.0%; 95% CI, 3.2-22.4%) for the ungrounded ChatGPT baseline, a paired improvement of 54.4 percentage points (95% CI, 36.8-72.0%). Conclusion: CLEAR-Med provides a general architecture for traceable analysis of structured clinical data: numerical claims remain linked to executed SQL, and unresolved cases can fail closed. The reported experiments characterize CLEAR-Med's configuration and scalability and the Invocation Agent's accuracy, while the formal analysis establishes the encoded-property guarantee of the complete control flow; a prospective full-pipeline evaluation of the validation and abstention stages is the next stage of this work.

Abstract:Objective: To develop and characterize CLEAR-Med, a dual-agent framework for natural-language analysis of structured clinical data that separates SQL-based invocation from independent validation. Methods: CLEAR-Med uses one agent to translate a question into executable Structured Query Language (SQL), retain the executed query and database result, and produce a draft. Deterministic checks and a separately invoked cross-provider Validation Agent then accept the draft, request one bounded repair, or abstain. We formalized the system as a bounded selective pipeline and evaluated CLEAR-Med's configuration and scalability, and the Invocation Agent's accuracy and consistency on a 25-query development benchmark, using a harmonized 21-site neonatal hypoxic-ischemic encephalopathy table containing 532 de-identified infant records and approximately 1,300 variables. Results: CLEAR-Med completed all six nominal scalability configurations, including 500x1300. Across 25 development-benchmark queries repeated five times, the Invocation Agent answered 83 of 125 responses correctly (66.4%; query-cluster bootstrap 95% CI, 48.0-83.2%), compared with 15 of 125 (12.0%; 95% CI, 3.2-22.4%) for the ungrounded ChatGPT baseline, a paired improvement of 54.4 percentage points (95% CI, 36.8-72.0%). Conclusion: CLEAR-Med provides a general architecture for traceable analysis of structured clinical data: numerical claims remain linked to executed SQL, and unresolved cases can fail closed. The reported experiments characterize CLEAR-Med's configuration and scalability and the Invocation Agent's accuracy, while the formal analysis establishes the encoded-property guarantee of the complete control flow; a prospective full-pipeline evaluation of the validation and abstention stages is the next stage of this work.

Artificial Intelligence (cs.AI)

arXiv:2609.34039 [cs.AI]

(or arXiv:2609.34039v1 [cs.AI] for this version)

https://doi.org/10.48550/arXiv.2609.34039 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 331 words

Related coverage