Skip to content
aiqbench takeMachine Learning

aiqbench analysis

This research introduces PEACE, a framework that leverages adult ECG pretraining and label-conditioned semantic descriptors to effectively address the scarcity of pediatric data. By integrating contrastive learning with curriculum-based fusion, the model achieves strong diagnostic performance while maintaining interpretability focused on clinically relevant waveform regions. The approach demonstrates a viable path for transferring large-scale medical AI capabilities to specialized domains with limited labeled samples.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Label-Conditioned Cross-Modal Fusion for Adult-to-Pediatric ECG Transfer via Curriculum-Gated Contrastive Alignment

arXiv3 min read

arXiv:2605.00647v2 Announce Type: replace Abstract: Automated pediatric electrocardiogram (ECG) interpretation remains challenging because developmental differences in heart rate, intervals, and waveforms limit the transferability of models trained mainly on adult data, while expert-labeled pediatric ECG cohorts are scarce. We propose PEACE (Pediatric-Adult ECG Alignment via Cross-modal Enhancement), an adult-to-pediatric ECG transfer framework pretrained on MIMIC-IV ECGs and adapted to pediatric targets. PEACE integrates label-specific bidirectional contrastive learning (LSBC) to align ECG representations with diagnostic semantics and curriculum adaptive fusion (CAF) to stabilize optimization under limited pediatric supervision. Label-conditioned short text descriptors provide auxiliary semantic supervision during training, whereas inference requires ECG signals only. On ZZU-pECG, PEACE achieves macro-average AUCs of 59.39%, 81.74%, and 91.56% under zero-shot, 50-shot, and full fine-tuning settings, respectively, outperforming ECG-only, multimodal, and generic domain adaptation baselines including DANN and MMD. On PTB-XL, it reaches 96.90% macro-average AUC after full fine-tuning over nine harmonized labels with nonzero mapped incidence. Gradient-based attention maps show increased saliency around QRS voltage and morphology regions for chamber-related RVH and around QRS-to-T/repolarization intervals for LQTS, broadly consistent with ECG regions commonly inspected during routine interpretation. These results suggest that adult-scale ECG pretraining coupled with rhythm, morphology, and ST-T repolarization semantic descriptors improves transferable pediatric diagnosis under label scarcity while preserving clinically interpretable waveform focus.

Abstract:Automated pediatric electrocardiogram (ECG) interpretation remains challenging because developmental differences in heart rate, intervals, and waveforms limit the transferability of models trained mainly on adult data, while expert-labeled pediatric ECG cohorts are scarce. We propose PEACE (Pediatric-Adult ECG Alignment via Cross-modal Enhancement), an adult-to-pediatric ECG transfer framework pretrained on MIMIC-IV ECGs and adapted to pediatric targets. PEACE integrates label-specific bidirectional contrastive learning (LSBC) to align ECG representations with diagnostic semantics and curriculum adaptive fusion (CAF) to stabilize optimization under limited pediatric supervision. Label-conditioned short text descriptors provide auxiliary semantic supervision during training, whereas inference requires ECG signals only. On ZZU-pECG, PEACE achieves macro-average AUCs of 59.39%, 81.74%, and 91.56% under zero-shot, 50-shot, and full fine-tuning settings, respectively, outperforming ECG-only, multimodal, and generic domain adaptation baselines including DANN and MMD. On PTB-XL, it reaches 96.90% macro-average AUC after full fine-tuning over nine harmonized labels with nonzero mapped incidence. Gradient-based attention maps show increased saliency around QRS voltage and morphology regions for chamber-related RVH and around QRS-to-T/repolarization intervals for LQTS, broadly consistent with ECG regions commonly inspected during routine interpretation. These results suggest that adult-scale ECG pretraining coupled with rhythm, morphology, and ST-T repolarization semantic descriptors improves transferable pediatric diagnosis under label scarcity while preserving clinically interpretable waveform focus.

Machine Learning (cs.LG)

arXiv:2605.00647 [cs.LG]

(or arXiv:2605.00647v2 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2605.00647 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 299 words