Skip to content
aiqbench takeMachine Learning

aiqbench analysis

This research introduces IQ-JEPA, a self-supervised framework using Hermitian vision transformers to efficiently estimate sound speed and attenuation from raw ultrasound data without relying on expensive labeled simulations. By leveraging unlabeled real-world acquisitions through masked prediction, the model achieves significant gains in label efficiency while maintaining accuracy comparable to supervised baselines. The approach represents a foundational step toward robust quantitative ultrasound models capable of generalizing across different tissue types with minimal retraining.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

IQ-JEPA: A Joint-Embedding Predictive Architecture with a Hermitian Vision Transformer for Sound Speed and Attenuation Estimation from Ultrasound IQ Data

arXiv3 min read

arXiv:2607.22351v1 Announce Type: new Abstract: The speed of sound in tissue is a prerequisite for well-focused imaging and has diagnostic value, but recovering it from raw pulse-echo channel data is fundamentally a nonlinear inverse problem. Learned solvers are fast yet label hungry. Simulated sound-speed labels are expensive, while abundant real channel data is unlabeled. We propose IQ-JEPA to exploit both data types. An encoder is pretrained without labels to predict the latent representation of masked in-phase and quadrature (IQ) regions from visible context, then fine-tuned on simulated maps. Sound speed appears in the IQ signal as a phase difference, invariant to the constant phase offset. The encoder is a Hermitian vision transformer that operates on the complex signal directly. Its attention is equivariant to that phase and its conjugate-product feed-forward is invariant to it, so the encoder reads a quantity analogous to the one classical coherence methods use. On 79,293 Fullwave 2.5 simulations at 2.5 MHz, pretraining on the 63,435 unlabeled acquisitions reaches 15.60 m/s at 10,000 labels. This is a roughly threefold gain in label efficiency over supervised training, growing to over fourfold at 1,000 labels. It is about 2.2x below an InversionNet baseline, and 8.71 m/s at full labels. The gain still grows with more unlabeled pretraining data. Our comparisons point to self-supervision as the dominant factor. The same encoder transfers. Its frozen features expose sound speed and attenuation, and cross-distribution pretraining between layered and abdominal phantoms costs little accuracy. We see this as a first step toward a foundation model for quantitative ultrasound.

Abstract:The speed of sound in tissue is a prerequisite for well-focused imaging and has diagnostic value, but recovering it from raw pulse-echo channel data is fundamentally a nonlinear inverse problem. Learned solvers are fast yet label hungry. Simulated sound-speed labels are expensive, while abundant real channel data is unlabeled. We propose IQ-JEPA to exploit both data types. An encoder is pretrained without labels to predict the latent representation of masked in-phase and quadrature (IQ) regions from visible context, then fine-tuned on simulated maps. Sound speed appears in the IQ signal as a phase difference, invariant to the constant phase offset. The encoder is a Hermitian vision transformer that operates on the complex signal directly. Its attention is equivariant to that phase and its conjugate-product feed-forward is invariant to it, so the encoder reads a quantity analogous to the one classical coherence methods use. On 79,293 Fullwave 2.5 simulations at 2.5 MHz, pretraining on the 63,435 unlabeled acquisitions reaches 15.60 m/s at 10,000 labels. This is a roughly threefold gain in label efficiency over supervised training, growing to over fourfold at 1,000 labels. It is about 2.2x below an InversionNet baseline, and 8.71 m/s at full labels. The gain still grows with more unlabeled pretraining data. Our comparisons point to self-supervision as the dominant factor. The same encoder transfers. Its frozen features expose sound speed and attenuation, and cross-distribution pretraining between layered and abdominal phantoms costs little accuracy. We see this as a first step toward a foundation model for quantitative ultrasound.

Machine Learning (cs.LG); Medical Physics (physics.med-ph)

arXiv:2607.22351 [cs.LG]

(or arXiv:2607.22351v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2607.22351 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 348 words