aiqbench analysis
This research achieves a fractional uncertainty of $4.3 \times 10^{-18}$ in comparing optical lattice and single-ion clocks, marking a critical step toward redefining the SI second via interspecies comparisons. The validation of transportable clock operation over nearly two years confirms their viability for chronometric geodesy without relying on fiber-optic links.
Interspecies clock comparison below $5 \times 10^{-18}$ uncertainty with a transportable clock
arXiv:2608.01916v1 Announce Type: cross Abstract: We report a measurement of the optical frequency ratio between the $^2\mathrm{S}_{1/2}(F=0)$--${^2\mathrm{F}_{7/2}(F=3)}$ electric-octupole (E3) transition of $^{171}$Yb$^{+}$ and the $^1\mathrm{S}_0$--${^3\mathrm{P}_0}$ transition of $^{87}$Sr, $\nu_{\mathrm{Yb}^{+}}/\nu_\mathrm{Sr} = 1.495\,991\,618\,544\,900\,588\,1(65)$. Reaching a fractional uncertainty of $4.3 \times 10^{-18}$, this result improves upon the previous best by more than a factor of three and is among the few that meet the requirements for interspecies clock comparisons specified by the roadmap towards the redefinition of the SI second. The comparison is between a transportable optical lattice clock and a stationary single-ion clock. It spans a period of nearly two years, during which the transportable clock was intermittently operated off-campus. The ratio was reproducibly measured during four separate campaigns, which are consistent within their statistical uncertainties. The results demonstrate reproducible $10^{-18}$ level operation of the transportable clock and thus validate its application for chronometric geodesy and as a transfer standard for inter-institute clock comparisons, e.g., in the absence of optical fiber links.
Abstract:We report a measurement of the optical frequency ratio between the $^2\mathrm{S}_{1/2}(F=0)$--${^2\mathrm{F}_{7/2}(F=3)}$ electric-octupole (E3) transition of $^{171}$Yb$^{+}$ and the $^1\mathrm{S}_0$--${^3\mathrm{P}_0}$ transition of $^{87}$Sr, $\nu_{\mathrm{Yb}^{+}}/\nu_\mathrm{Sr} = 1.495\,991\,618\,544\,900\,588\,1(65)$. Reaching a fractional uncertainty of $4.3 \times 10^{-18}$, this result improves upon the previous best by more than a factor of three and is among the few that meet the requirements for interspecies clock comparisons specified by the roadmap towards the redefinition of the SI second. The comparison is between a transportable optical lattice clock and a stationary single-ion clock. It spans a period of nearly two years, during which the transportable clock was intermittently operated off-campus. The ratio was reproducibly measured during four separate campaigns, which are consistent within their statistical uncertainties. The results demonstrate reproducible $10^{-18}$ level operation of the transportable clock and thus validate its application for chronometric geodesy and as a transfer standard for inter-institute clock comparisons, e.g., in the absence of optical fiber links.
Atomic Physics (physics.atom-ph); Quantum Physics (quant-ph)
arXiv:2608.01916 [physics.atom-ph]
(or arXiv:2608.01916v1 [physics.atom-ph] for this version)
https://doi.org/10.48550/arXiv.2608.01916 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 252 words
Related coverage

Singapore Scientists Claim They Built The World’s Most Accurate Atomic Clock
The Quantum Insider · Sep 24, 2026

Quantum Lutetium clock at CQT sets new world record for timekeeping
Quantum Zeitgeist · Sep 24, 2026

Lattice-Based Cryptography Explained
Quantum Zeitgeist · Aug 15, 2026
Under Violet
LessWrong · Jun 10, 2026